Technical Data - Aventics RMV AS-i/Aux Instrucciones De Servicio

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

English
1
Safety notes
W
The bus coupler is to be used exclusively in bus systems according to
specifications AS-i.
W
This is a class A product. In a living environment this product can cause
radio interference, in which case it may be necessary for the user to take
appropriate measures.
W
Installation should only be done by trained specialists.
W
Only operate the bus coupler in a completely assembled state. Always
turn off the power when plugging and unplugging the plug connectors.
W
The power supply must be installed in such a way that no surge voltages
can occur on the output side.
W
The bus coupler has an integrated watchdog function, which resets the
outputs in the event of a bus communication failure.
2
Addressing the bus coupler
Connect the plug (10) to the programming device using an addressing cable.
Assign an address from 1 to 31 and document it on the label (8), (14).
The bus coupler address set at the factory is: 0
3
Connecting the bus cable
Connect the yellow profile cable (13) to the plug (10) via the AS-i cable socket
(12).
Status-LED (6) and (7):
POWER
FAULT
off
off
green
off
green
red
4
Connecting the load supply
Connect the black profile cable (15) to the load supply plug (11) using the
cable socket (16). Connect the power supply for the load supply (5) to the
black cable (see "Technical data" for specifications).
+24 V: brown, 0 V: blue.
LED (9) is lit: load supply voltage is on.
This way the valves are supplied separately from the bus coupler and can be
turned off in case of an emergency shut-down (4) while the bus coupler
remains functioning.
5
Triggering the valves
The valves are triggered by the bus coupler's (3) 4 outputs according to the
following allocation scheme.
Data bit
Valve location
1
2
D0
solenoid 14
D1
solenoid 14
D2
solenoid 12
D3
solenoid 12
Meaning
No supplyvoltage present at bus
Cyclic I/O data traffic
No I/O data traffic
3
4
solenoid 14
solenoid 14
AVENTICS | RMV AS-i/Aux | 1987765503–BDL–001–AB
6

Technical data

Characteristics
General
Degree of protection
IP 65 (EN 60529/IEC 529) when assembled.
Ambient temperature
0°C to +50°C
Bus coupler
Rated voltage
according to AS-i specifications 26,5 V ... 31,6 V
Power consumption
40 mA
I/O-Code
8
ID-Code
F
ID2-Code
E
Load supply 24 VDC ext.
Rated voltage
24 VDC (-15%/+20%) protective minimal
voltage (PELV) according to IEC 364-4-41
Residual ripple
0,5%
Current per valve
50 mA
solenoid
Electromagnetic compatibility
Interference signal/
EN 50295
Interference immunity
Accessories (order separately)
Cable socket
1 824 484 064
(1 piece) incl. label
Addressing cable
on request
7
Figure legend
1 Master
2 Power supply
3 Bus coupler
4 Emergency off relay
5 Power supply for load supply
6 LED POWER (supply, green)
7 LED FAULT (status, red)
8 Identification field
9 LED AUX (load supply green)
10 Plug bus connection (PWR)
11 Plug load supply (AUX)
12 Cable socket bus connection
13 Yellow profile cable
14 Label
15 Black profile cable
16 Cable socket load supply