Air losses
These can be caused by poor tightness of a union - check all unions, wetting them with soapy water.
© Stanley Bostitch
Compressor not starting
GB Not to be reproduced without permission. Unauthorised copies of this document do not constitute CE
If the compressor has trouble starting, check the following :
compliance for the products.
-Does mains power match that of the data-plate? (fig. 5)
-Are power cable extensions of adequate diameter or length?
-Is the work environment too cold? (under 0°C)
FR Reproduction interdite sans permission préalable. Les copies non autorisées de ce document ne signifient en
-Is there oil in the housing to ensure lubrication?
rien que les produits soient conformes aux normes CE.
-Is power supplied to the electrical line? (sockets well connected, thermal- breaker, fuses in good condition).
DE Vervielfältigung nicht ohne Genehmigung gestattet. Unzulässig erstellte Kopien dieses Dokuments erfüllen nicht
Compressor not stopping
die CE-Richtlinien für Produkte.
-If the compressor does not stop when maximum pressure is reached, the tank safety valve comes into operation. To
repair the valve, contact your nearest service centre.
NL Mag niet worden vermenigvuldigd zonder toestemming. Onrechtmatige kopieën van dit document willen niet
IMPORTANT
zeggen dat de producten voldoen aan de CE-vereisten.
-Do not on any account unscrew any connection while the tank is pressurised
-Always check if the tank is pressure free.
-Do not drill holes, weld or purposely deform the compressed air tank.
DK Må ikke gengives uden tilladelse. Uautoriserede kopier af dette dokument udgør ikke CE overholdelse for
-Do not do any jobs on the compressor unless you have disconnected the power plug.
produkterne.
-Temperature in operating ambient: 0°C +35°C.
-Do not aim jets of water or inflammable liquids on the compressor.
FI Ei saa jäljentää ilman lupaa. Tämän asiakirjan ilman valtuutusta tehdyt kopiot eivät muodosta tuotteille CE-
-Do not place flammable objects near the compressor.
yhdenmukaisuutta.
-During down-times, turn the pressure switch to position "0" (OFF).
-Never aim the air jet at people or animals
-Do not transport the compressor while the tank is pressurised.
GR Απαγορεύεται η αναπαραγωγή χωρίς προηγούμενη άδεια. Τα μη εξουσιοδοτημένα αντίγραφα του παρόντος
-Be careful with regard to some parts of the compressor such as the head and delivery tubes, as they can reach high
εγγράφου δεν αποτελούν συμμόρφωση CE για τα προϊόντα.
temperatures. Do not touch these parts to avoid burns.
-Transport the compressor, lifting or pulling it with the appropriate grips or handles
IT Vietata la riproduzione senza permesso. Le copie non autorizzate di questo documento non garantiscono la
-Keep children and animals well away from the machine operating area.
conformità CE per i relativi prodotti.
-If using the compressor for painting: a) Do not work in closed environments or near to naked flames b) Make sure
there is adequate exchange of air at the place of work c) Protect your nose and mouth with an appropriate mask.
Consult the tool / accessory manual and adhere to any safety requirements.
NO Skal ikke reproduseres uten tillatelse. Ikke godkjente kopier av dette dokumentet oppfyller ikke kravene for CE-
-If the electrical cable or plug are damaged, do not use the compressor and contact an authorised service centre to
merking for produktet.
replace the faulty element with an original spare part.
-If the compressor is located on a shelf or on a top above floor height, it must be secured to prevent it falling while in
operation.
PT Reprodução proibida sem autorização prévia. As cópias não autorizadas deste documento não estão em
-Do not put objects or your hands inside the protective grilles to avoid injury to yourself or damaging the compressor.
conformidade com a CE para os produtos.
-Do not use the compressor as a blunt object toward things or animals, to avoid serious damage.
-When you have finished using the compressor, always remove the plug from the power socket.
ES Prohibida la reproducción sin permiso. Las copias no autorizadas de este documento no suponen la
conformidad con las normas CE de los productos.
ELECTRO-COMPRESSOR MODELS
For the European market, the compressor tanks are manufactured to meet Directive 2009/105/EC For the European
market, the compressors are manufactured to meet Directive 2006/42/EC.
SE Prohibida la reproducción sin permiso. Las copias no autorizadas de este documento no suponen la
Acoustic pressure measured free-field at a distance of 4m at maximum operating pressure.
conformidad con las normas CE de los productos.
Model
PL Niniejszy dokument nie może być kopiowany bez pozwolenia. Nieautoryzowane kopie niniejszego dokumentu nie
stanowią deklaracji zgodności CE prezentowanych produktów.
Tank Size (Ltr)
Horse Power / Kilo Watts Peak
CZ Niniejszy dokument nie może być kopiowany bez pozwolenia. Nieautoryzowane kopie niniejszego dokumentu nie
Horse Power / Kilo Watts Running
stanowią deklaracji zgodności CE prezentowanych produktów.
Running Amps
SK Rozmnožovanie bez povolenia je zakázané. Neoprávnené kópie tohto dokumentu nie sú v súlade s CE pre dané
Pump Type
výrobky.
Lwa dB(A) @ 4m
Lp dB(A) @ 4m
Maximum Working Presure (BAR / PSI)
HU A dokumentum engedély nélkül nem sokszorosítható. Az engedély nélkül sokszorosított dokumentum nem jelenti
Air Displacement (Ltr/Min / CFM)
a termék CE-megfelelőségét.
Air Delivery ((Ltr/Min / CFM) @ 7 Bar)
Volts
RO Reproducerea neautorizată este interzisă. Copiile neautorizate ale acestui document nu reprezintă
Weight (Kgs)
conformitatea CE pentru produse.
MRC6
C24
C24-U110
6
24
1.5 / 1.1
2.5 / 1.8
2.5 / 1.8
1.5 / 1.1
2.2 / 1.6
2.2 / 1.6
5.5
7.5
Oil-Free
Oil Lubricated Oil Lubricated Oil Lubricated
96.0
94.0
94.0
74.0
72.0
72.0
8 / 116
10 / 145
10 / 145
170 / 6.0
233 / 8.2
233 / 8.2
75
108
230v
230v
110v
10.5
25
C50
RC-10
24
50
10
2.5 / 1.8
2.0 / 1.5
2.2 / 1.6
1.85 / 1.4
14
7.5
6
Oil-Free
94.0
97.0
71.2
75.5
10 / 145
10 / 145
233 / 8.2
216 / 7.6
100
108
82
230v
230v
25
36
18
RC-10-U110
PS20
PS20-U110
10
20
2.0 / 1.5
2.5 / 1.8
2.5 / 1.8
1.85 / 1.4
2.3 / 1.7
2.3 / 1.7
6
8
Oil-Free
Oil Lubricated Oil Lubricated
97.0
96.0
75.5
74.8
10 / 145
10 / 145
10 / 145
216 / 7.6
240 / 8.5
196 / 6.9
82
138
110v
230v
18
35
20
15
96.0
74.8
100
110v
35