English; Terminal Control, Keypad Control - Control Techniques COMMANDER SE Puesta En Marcha Rapida

Ocultar thumbs Ver también para COMMANDER SE:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

COMMANDER SE QUICK START
As default - in positive logic (connect terminals to +24V to activate).
Parameter 5 set to A1. A2.
10kΩ
(2kΩ min)
-
0-10V
V
+
4-20mA
+24V
0V
Connect terminals 7 & 9
Set parameter 5 to PAd. If reverse is required, set parameter 10 to L2 and set parameter 26
to On to enable
Press
key to reverse and
NOTE! When parameter 5 is set to PAd, terminals 12 and 13 do not have any functionality.
Improper procedures can result in personal injury or equipment damage.
!
Use this Quick Start Guide only if you are familiar with standard safety
precautions common to electronic drives. See Commander SE User
WARNING
Guide for details.
ÈÉ
TERMINAL CONTROL
1
0V common
2
Local voltage speed reference input (A1)
3
+10V reference output
4
0V common
5
Remote current speed reference input (A2)
6
Analog output (Motor speed)
7
+24V output
8
Digital output (Zero speed)
9
Drive Enable / Reset
10
Run Forward
11
Run Reverse
12
Local (A1) / Remote (A2) speed reference
13
Jog Select
14
+24V output
15
OK
16
KEYPAD CONTROL
key. Use and
keys to increase/decrease speed. Press
O
key to stop.
FAULT
+24V
7
Drive Enable
9
1
I
key to go.