Notes For Maintenance Technicians; Routine Maintenance; Information For The User - Aprimatic PTR-24 Instrucciones Para La Instalación Electrica, El Uso Y El Mantenimiento

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

CONTROL UNIT
6.

NOTES FOR MAINTENANCE TECHNICIANS

• Compliance with Machinery Directive 98/37/EC: When you have installed the equipment, you must complete a Declaration of
Conformity and a Scheduled Maintenance Plan in compliance with the directive and then hand over copies of these documents
to the user.
6.1

Routine maintenance

You should ask the company that installs the automation to provide a scheduled maintenance plan in compliance with the
regulations for this type of equipment (for EU countries: Machinery Directive 98/37/EC).
• We recommend that you program the maintenance cycle on the unit (see the section Programming).
When the present number of cycles is reached, the display will fl ash rapidly at start up and when you start programming the
MAN
message will appear fl ashing for approx. 3 seconds. These signals indicate that you should proceed with maintenance.
When you have completed maintenance, program a new cycle on the unit (see the section Programming).
The maintenance intervals and operations recommended by Aprimatic S.p.A. for the electrical equipment are as follows.
Operation
Check the effi ciency and adjustment of
safety devices and the anti-crush device.
Check the photocells, the detector and the
safety edge.
Check the effi ciency of the electrical
equipment. Test the effi ciency of the
differential overload switch protecting the
unit.
Check the inside of the electrical box. Clean
out any insects, dirt or dampness.
Check the effi ciency of the optional
emergency batteries (where installed).
Change spent batteries.
Remove branches, bushes or other
obstacles which might permanently obstruct
or interrupt the photocell beam.
7.

INFORMATION FOR THE USER

This instruction manual is an integral part of the product. The instructions and warnings must be given to the user and
then read carefully because they include important warnings for use and maintenance. The instructions must be kept and
given to all future users.
Use this equipment for the permitted uses only. All other uses constitute improper use. All improper use is forbidden and
hazardous.
Do NOT tamper with or modify the product in any way.
Perform maintenance at the recommended intervals. See the maintenance manual and schedule issued by the installer.
Keep remote control and other control units in a safe place to prevent use by children or unauthorised people.
Only suitably skilled technicians trained on the product are authorised to connect up, test, put into service, clean and maintain
this product.
In the event of any faults, switch off the mains power supply at the main On-Off switch. No user serviceable parts inside. Do
not try to repair the main unit. Contact the installer or other specialist assistance centre. Failure to follow these instructions
may result in hazardous situations.
!
Warning
No user serviceable parts inside. Do not attempt to repair the equipment or control unit. Do not open the electrical box. In the
event of an operating fault or a mains power failure you can OPERATE THE BARRIER BEAM BY HAND. (For instructions,
see the barrier installation manual).
Aprimatic S.p.A.
via Leonardo da Vinci, 414
40059 Villa Fontana di Medicina - Bologna - Italia
Tel. +39 051 6960711 - fax +39 051 6960722
info@aprimatic.com - www.aprimatic.com
Average
interval
!
Every 6
Warning
months
Before you start any maintenance operations, disconnect
the automation from the mains power supply using the
system electrical differential switch. If emergency batteries
Every 6
are fi tted, disconnect these too!
months
Batteries are consumables and as such are not covered by
Every 6
the guarantee.
months
Do not throw away old batteries with household waste. Dispose
Every 6
of old batteries using the old battery containers provided at
months
sales outlets.
Every 6
months
SPACE RESERVED FOR INSTALLER
WHEN YOU HAVE COMPLETED INSTALLATION GIVE THE INSTRUCTIONS TO THE USER.
- 32 -
PTR-24

Publicidad

Tabla de contenido
loading

Tabla de contenido