Electrical wiring

- Before proceeding to the electrical wiring, make sure it is disconnected from the electrical supply. Also make
sure that the impeller rotates freely and there are no obstructions in the inlet or outlet fan.
- Make sure the voltage and frequency of the network coincide with the technical values determined in the
technical plate.
- Electrical wiring HV-150 M model: according to scheme figure C.
- Electrical wiring HV150 AE model: according to scheme figure C.
- Electrical wiring HV-150 A model: according to scheme figure D.
(To operate all these functions use the accessory CR-150 of S&P)
Operation mode
HV-150 M Model
(Manually operated via pull cord)
3 operation modes via pull cord
Mode 1
Fan Off – Shutter closed
Mode 2
Fan Off – Shutter open (natural ventilation).
Mode 3
Fan On- Working as air extract (Mechanical ventilation)
HV-150 AE Model
2 operation modes:
Mode 1
Fan Off – Shutter closed
Mode 2
Fan On – Working as air extract
HV-150 A Model
(To operate all these functions use the accessory CR-150 of S&P)
3 operation modes:
Mode 1
Fan Off – Shutter closed
Mode 2
Fan Off – Shutter open (Natural ventilation).
Mode 3
Fan On – Working as air extract (Mechanical
OFF: Shutter closed / air extract closed
ON +
: Shutter open / air extract closed (natural ventilation)
ON +
: Shutter open / working as air extract (mechanical ventilation)
ATTENTION: The CR-150 control of S&P is delivered with a joint between contacts 5-1. This joint
has to be moved, so that the joint is positioned between contacts 5-2.
NOTE: One CR-150 of S&P can control up to 5 HV-150A.
Maintenance
- Before handling the fan, make sure it is disconnected from the mains supply
- Clean regularly with a soft cloth moistened with water.
- Periodically check the state of the impeller
- Do not clean with pressure water jet.
Removal from service, disposal and recycling
The CEE norm and our commitment to future generations require us to recycle waste material;
please deposit all remaining elements of the packaging into containers for recycling, and take the
equipment that has been replaced to the nearest waste centre or your dealer.

Technical assistance

The extensive S&P Official Services Network guarantees competent technical assistance anywhere in
Spain.
If any anomalies are observed in the appliance, please contact any of the Technical Services on the list to deal
with your problem.
Any handling of the appliance by persons other than S&P Official Services will lead to the guarantee being
cancelled.
S&P reserves the right to make any modifications without prior notice.