Storing Machine; Recommended Stock Items; Trouble Shooting - Tennant 5200 Manual De Operación Y De Piezas

Fregadora automática batería
Ocultar thumbs Ver también para 5200:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

STORING MACHINE

Store machine in a dry area in the upright position.
Before storing machine be certain to flush tanks and
drain machine of all water. Remove recovery tank lid
to promote air circulation. Raise pad driver and
squeegee off floor to prevent damage.
ATTENTION If storing machine in freezing
temperatures, be certain to drain machine of all
water. Damage due to freezing temperatures is not
covered by warranty.
ATTENTION: Do not expose machine to rain; store
indoors.

TROUBLE SHOOTING

PROBLEM
No power.
Brush motor does not run.
Vacuum motor does not run.
Short run time.
(Run time 2.47 hours on full charge)
(Run time 2.47 hours on full charge)
Safety lights do not work.
Little or no solution flow.
Tennant 5200 Battery (01–02)
CAUSE
Batteries need charging.
Battery(s) faulty.
Loose battery cable.
Batteries are not connected
correctly.
Faulty brush switch.
Machine circuit breaker has tripped. Clean or replace pad or brush and
Rectifier has burned out.
Faulty wiring.
Faulty brush motor.
Carbon brushes worn.
Faulty solenoid.
Faulty vacuum switch or wiring.
Faulty vacuum motor.
Carbon brushes worn.
Batteries not fully charged.
Bad cell in one or more batteries.
Batteries need maintenance.
Faulty charger.
Flasher is burned out.
Solution flow lever is not activated.
Solution line is clogged.
Solution valve is clogged.
Solution flow adjustment knob
needs adjusting.
Home Find... Go To..

RECOMMENDED STOCK ITEMS

Refer to Parts List section for recommended stock
items. Stock Items are clearly identified with a bullet
preceding the parts description. See example below:
SOLUTION
See Battery Charging.
Replace battery(s)
Tighten loose cables.
See Battery Installation.
Contact Service Center.
reset breaker button.
Contact Service Center.
Contact Service Center.
Contact Service Center.
Contact Service Center.
Contact Service Center.
Contact Service Center.
Contact Service Center.
Contact Service Center.
Charge batteries.
Replace battery.
See Battery Maintenance.
Replace charger.
Contact Service Center.
Push solution flow lever forward.
Remove hose and blow
compressed air through it.
Remove valve and clean. Do not
scratch or damage inside of valve.
Adjust solution flow knob to
increase solution flow. Turn knob
down to increase flow.
OPERATION
13

Publicidad

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

612950612951612952

Tabla de contenido