Festo ELGA-TB-G Instrucciones De Utilizacion página 35

Ocultar thumbs Ver también para ELGA-TB-G:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

ELGA-TB-G/-KF/-RF
• Set down nominal load in such a way that the tilt moment result­
ing from force F (parallel to the axis of movement) and lever arm
are kept as small as possible.
• Avoid collisions of tool and payload with attachments.
For attachment components with their own guide:
• Adjust the guides of the tool and axis so that they are exactly parallel, or use a connection that
permits tolerance compensation. In this way, you will avoid overloading the guide.
Mounting
• Fasten the attachment to the slide with screws and centring
sleeves.
• Maintain maximum screw-in depth D and tightening torque
(è Tab. 2).
Size
Screw
tightening torque
Max. screw-in depth D
Centring H7
Tab. 2
Festo – ELGA-TB-G/-KF/-RF – 1512d English
70
M5
[Nm]
5.9
[mm]
7.5
@ 5
G, KF
[mm]
@ 9
KF, RF
[mm]
a
Fig. 10
Fig. 11
Fig. 12
80
120
M5
M6
M5
M6
5.9
9.9
5.9
9.9
9.5
12.5
@ 9
F
150
M6
M8
9.9
24
14
35

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Elga-tb-kfElga-tb-rf

Tabla de contenido