Descargar Imprimir esta página

salmson SIRIUX O home Instalacion Y Puesta En Servicio página 32

Publicidad

Idiomas disponibles

Idiomas disponibles

English
6 Operation
NOTE: All settings and displays are retained if the power supply is interrupted.
6.1 Resetting the power consumption meter
• Press the red operating knob (8) for 10 seconds when in downtime status.
-> The meter reading flashes 5 times before resetting to zero.
6.2 Resetting the settings to the factory settings
• Press the red operating knob (8) for 20 seconds when in downtime status.
-> All LED segments light up for 2 seconds. The pump is then reset to its factory
settings and the power consumption meter is at zero.
7 Decommissioning
Shutting down the pump
Shut down the pump immediately in case of damage to the connecting cable or
other electrical components.
• Disconnect the pump from the power supply.
• Contact Salmson customer service or a qualified specialist technician.
8 Service
Cleaning
• Carefully remove soiling from the pump on a regular basis using a dry duster.
• Never use liquids or aggressive cleaning agents.
32
5.4 Deactivating key lock
• Use the red operating knob (8) to select the "Thermal
disinfection" menu.
• Press the red operating knob (8) for 10 seconds.
-> The display (7) shows Hold and ON alternately.
• Select the OFF setting.
• Press the red operating knob.
-> The key lock is deactivated.
02/2015

Publicidad

loading