Operating Instructions (Continued)
4. Heater Control Button:
This button controls the heater ON/OFF and 11 temperature modes from 68°F (20°C) to 88°F (31°C). When the
heater is first turned on, it will come on at the lowest room temperature setting 68°F (20°C). Each time the Heat-
er Control button is pressed, the temperature set point increases 2°F (1°C), allowing you to adjust the ambient
temperature, up to 88°F (31°C). The fireplace will remember the last heat setting, and in later use, the heater will
start at that setting, unless power to the unit has been interrupted.
NOTE: To switch between Fahrenheit/Celsius modes see
control panel Fahrenheit/Celsius display instructions.
Maintenance
DANGER: Disconnect power before servicing.
WARNING: Any electrical re-wiring of this appliance must be done by a qualified electrician. This
wiring must be done in accordance with local codes and/or in Canada with the current CSA C22.1
Canadian Electrical Code, and for US installations, the National Electrical Code ANSI/NFPA NO 70.
WARNING: If repairing or replacing any electrical component or wiring, the original wire routing, color
coding and securing locations must be followed.
GLASS INFORMATION
1. Under no circumstances should this product be operated with a broken or chipped glass panel.
2. Do not strike or slam the glass.
3. Do not use abrasive cleansers to clean the glass. Make sure the glass is cool to the touch.
4. This product uses tempered glass. Replacement of the glass supplied by the manufacturer should be done
by qualified/authorized service personnel only.
1. Always disconnect the appliance from the main power supply and allow it to cool before any servicing
operation.
2. The motors used on the fan heater and flame blower are pre-lubricated for extended bearing life and
require no further lubrication. However, periodic cleaning/vacuuming of the appliance around the air
intake and exhaust, as well as the fan heater is reccomended. For heavy or continous use, periodic
cleaning must be done more frequently. If the heater blows alternating cold and warm air, check the fan
for free movement and for debris restricting air flow. If the fan does not move freely, the unit be turned off
and fan replaced immiediately in order to prevent further damage to the unit.
Care and Cleaning
1. Always turn the heater OFF and unplug the power cord from the outlet before cleaning.
2. Cleaning of the control panel, located in the upper right-hand corner of the fireplace is to be done only
using a soft cloth, slightly dampened in water (if needed, a small amount of dish soap can be added to
the water) and dried using a clean, dry soft cloth. Cleaning of the screen diffuser is to be done using only
water and lint free cloth. DO NOT use any abrasive on the controls or the diffusing screen.
MAINTENANCE OF MOTORS
9