Features
• Easy installation with strip terminal
• Tight regulation: 0.05% Line; 0.05% Load
• Full Output Ratings to +50
C
o
• Built in OVP on 5 Volt Outputs
• OVP Option for 12V, 15V and 24V
• Foldback Current Limiting Overload Protection with
Automatic Recovery
General Specifications
Voltage/Current Ratings
Model Numbers
SLS-05-120-1T
SLS-12-068T
SLS-15-060T
SLS-24-048T
Operating Temperature Range
0 to +50
o
Temperature Coefficient (Typical)
+/- 0.01% /
Stability
Within +/- 0.05% (24 hours after warm-up)
Vibration
Per MIL-STD-810C, Method 514
Shock
Per MIL-STD-810C, Method 516
Linear power supplies have inherently low conducted and radiated noise levels.
For most system applications, these power supplies will meet the requirements
EMI/RFI
of FCC Class "B" and VDE 0871 for Class "B" equipment without additional
noise filtering.
Forced air. 20 CFM required for full rating Derate 30% for convection cooling.
Cooling
100/120/220/230/240 VAC selectable +/- 10% except 230 VAC is +15%, -6%
Multi Input (all units)
Frequency Range
47-63 Hz (Typical is 60 Hz. Derate output 10% at 50 Hz)
50 µsec at 50% load changes for outputs rated up to 6A
Transient Response Time
100 µsec at 50% load changes for outputs rated 6A and over.
Units are not fused internally. For safe operation, user must provide input line
Fuse Requirements
fuse as per values given in table.
0.05% for +/- 10% change
Line Regulation
0.05% for 50% change
Load Regulation
3.0 mV maximum peak-to-peak
Ripple
DC Output Adjustment Range
+/- 5% minimum
All 5 volt outputs include built-in OVP standard (setting is 6.2V +/- 0.4 V). OVP
Overvoltage Protection
is optionally available on other outputs
All units have remote sensing capability.
Remote Sensing
Overload Protection
125 to 150% foldback current limit
Linear Open Frame DC Power Supplies
Silver Line Instruction Manual
Models: SLS-05-120-1T, SLS-12-068T,
SLS-15-060T, SLS-24-048T
• Multi-Tap AC Inputs
• 100% Four-Hour Burn-in
• Please see enclosed "Terms & Conditions and
Sales & Policies & Procedures"
• UL Recognized
• CSA Certified
• CE Marked
• CB Certified
Output (Volts)
Output (Amps)
5
12
15
24
C (Derate to 40% at +70
C)
o
o
C
Input Specifications
Output Specifications
Input AC Connections (See Case I2)
For use
at:
100 VAC
120 VAC*
220 VAC
230 VAC
240 VAC
Mechanical Dimensions: Inches (mm)
12.0
6.8
6.0
4.8
Application Note: User needs to provide earth ground to power supply with either solder to Tab or using washer and
OVP (OPTIONAL)
9.00" (229)
. 512" (13)
8.00" (203)
Apply AC
Primary Fuse
Connect
to:
SLS-05-120-1T
1-3, 2-4
1 & 5
2 A / 125 V
1-3, 2-4
1 & 4
2 A / 125 V
2-3
1 & 5
1 A / 250 V
2-3
1 & 4
1 A / 250 V
2-3
1 & 4
1 A / 250 V
*Note: Unit is shipped for 120V input from factory.
. 473" (12)
OVP (OPTIONAL)
AC INPUT/DC OUTPUT
9.00" (229)
. 512" (13)
8.00" (203)
R14
V.ADJ
. 75" (19)
R13
I.LIM
. 188"
. 473" (12)
(4.8 )
°
MTG HOLES (12 PLACES)
5
1
3
2
4
AC Input
5V
. 75" (19)
Case I1
5
1
3
2
4
5
1
3
2
3
5
1
2
4
AC Input
5V
12V
AC Input
Case I1
AC Input
5
1
3
2
4
Case I2
Case I2
AC Input
Note: The SLS models DC output can be adjusted with R14 V. ADJ.
Case I2
R13 I. LIM is factory set and should not be adjusted by users.
nut assembly.
The SLS power supply is shipped from the factory with metal shorting straps connected between
the + OUT and + S terminals and the (-) OUT and (-) S terminals. This strapping configuration
allows the output of the SLS to be taken from either pair of terminals. This is the
standard configuration.
The remote sense feature is enabled by removing the shorting straps and connecting the
individual OUT and S terminals to the appropriate points of the load. If an OVP circuit is used it
should be connected to the + OUT and (-) OUT terminals. The OVP should never be connected
to the + S, - S terminals without the use of the shorting straps. In all cases it is critical that the
terminal screws be firmly tightened.
Contact Technical Services at 1-800-377-4384 or tech@sola-hevi-duty.com with any questions.
Visit our website at www.solaheviduty.com
AC INPUT/DC OUTPUT
1.250" (32)
Primary Fuse
Primary Fuse
SLS-15-060T
SLS-24-048T
SLS-12-068T
Please
2.5 A / 125V
3.0A / 125V
See
Voltage
2.5 A / 125V
3.0A / 125V
&
Current
1.25A / 250V
1.5A / 250V
ADJ
Placement
1.25A / 250V
1.5A / 250V
Diagrams
1.25A / 250V
1.5A / 250V
. 188"
(4.8 )
°
MTG HOLES (12 PLACES)
WEIGHT: 7. 5 LBS.
(3.4 KG)
1.250" (32)
. 75" (19)
. 551" (14)
MAX
PEM NUT HOLES
8-32 MTG (4 PLACES)
WEIGHT: 7. 5 LBS.
5
1
3
2
4
(3.4 KG)
AC Input
12V
12/15V
12/15V
PEM NU T H OLES
8-32 MT G ( 4 P LACES)
Case I3
4
12/15V
5
1
3
2
4
12/15V
Case I3
AC Input
5
1
3
2
4
AC Input
Case I4
Case I4
. 75" (1
. 551"
M