Chapter 3,

ALTAIR Pro Function Checks

Confidence and Heartbeat Indicator

The alarm lights and heartbeat indicator on the display will
flash approximately every 60 seconds to indicate that the
ALTAIR Pro Detector is operating.

Alarm Test

Check before each day's use.
Turn ON instrument. A one-second test of the alarms will occur;
this includes the:
display
alarm lights
vibrator
horn.
If these items do not activate, remove the instrument from service.
NOTE: For the Steel Mill version only, the alarm test occurs every
time the button is pressed for one second.

Bump Test

Check before each day's use.
Hold the TEST button for two seconds:
oxygen versions will display the current oxygen reading;
calibrate the unit if it reads other than 20.8%.
"TEST" "GAS" "?" will display.
Press the TEST button while "TEST" "GAS" "?" displays to activate
the Bump Test mode.
the hourglass and "GAS" will display.
Apply gas only AFTER the hourglass and "GAS" are displayed.
If gas is detected, the display will indicate "OK".
NOTE:
Wait approximately five seconds:
The "√" that appears on the display:
indicates that the instrument passed the bump test.
remains for 24 hours, indicating that a bump test
was performed on this instrument within the last
24 hours.
See TABLE 3-1 for applied gases.
3-1