Chapter 3,
ALTAIR Pro Function Checks
Confidence and Heartbeat Indicator
•
The alarm lights and heartbeat indicator on the display will
flash approximately every 60 seconds to indicate that the
ALTAIR Pro Detector is operating.
Alarm Test
•
Check before each day's use.
•
Turn ON instrument. A one-second test of the alarms will occur;
this includes the:
•
display
•
alarm lights
•
vibrator
•
horn.
•
If these items do not activate, remove the instrument from service.
NOTE: For the Steel Mill version only, the alarm test occurs every
time the button is pressed for one second.
Bump Test
•
Check before each day's use.
•
Hold the TEST button for two seconds:
•
oxygen versions will display the current oxygen reading;
calibrate the unit if it reads other than 20.8%.
•
"TEST" "GAS" "?" will display.
•
Press the TEST button while "TEST" "GAS" "?" displays to activate
the Bump Test mode.
•
the hourglass and "GAS" will display.
•
Apply gas only AFTER the hourglass and "GAS" are displayed.
•
If gas is detected, the display will indicate "OK".
NOTE:
•
Wait approximately five seconds:
•
The "√" that appears on the display:
•
indicates that the instrument passed the bump test.
•
remains for 24 hours, indicating that a bump test
was performed on this instrument within the last
24 hours.
See TABLE 3-1 for applied gases.
3-1