Pressure Relief Procedure - Tritech T7 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

Pressure Relief Procedure

The sprayer's pressure must be manually relieved to prevent sprayer from starting or spraying accidentally.
Fluid under high pressure can be injected through skin and cause serious injury. To reduce risk of injury from
injection, splashing fluid, or moving parts,
Follow the Pressure Relief Procedure whenever you:
• are instructed to relieve pressure
• stop spraying
• check or service any system equipment
• install or clean spray tip
PROCEDURE
1. Turn pressure control knob counterclockwise to stop.
2. Turn sprayer off.
3. Do not unplug power supply cord.
4. Hold metal part of gun firmly to grounded metal container. Trigger gun to relieve pressure.
5. Lock gun safety latch.
6. Open pressure relief valve. Leave pressure relief valve open until ready to spray again.
NOTE: Do not store unit for extended periods of time with the Pressure Relief Valve open. Store the unit in the
spray position.
NOTE: If suspected that spray tip or hose is completely clogged, or that pressure has not been fully relieved after
following steps above,
SLOWLY loosen tip guard or hose end coupling to relieve pressure gradually, and then loosen completely. Clear
tip or hose obstruction.
ELECTRICAL SHOCK WARNING
To reduce risk of serious injury, including electric shock, do not touch moving or electrical parts with fingers or
tools while testing repair. Shut off and unplug sprayer when inspection is complete. Install all covers, guards,
gaskets, screws and washers before operating sprayer.