2. Important Safety Instructions
• Save all packing materials for later use. Repacking and shipping the Distribution Center without the original packing
materials may cause product damage not covered by the warranty.
• Do not attempt to unpack or move the Distribution Center without assistance. Use appropriate handling equipment rated
to bear the weight and bulk of the Distribution Center, such as freight elevators, pallet jacks and forklifts. (Fully extend forks
under load. Spread forks to maximum possible width under load. Lift cabinet from bottom only. Wear safety shoes.) Confirm
that load limits for freight elevators, handling equipment and floors along the transport route will not be exceeded by the
combined weight of the packaged Distribution Center, handling equipment and personnel. Confirm that the Distribution
Center will pass through any doorways along the intended route.
• The Distribution Center is secured with stretch wrap to protect it during shipping and movement within a facility. Remove the
stretch wrap from the Distribution Center when the Distribution Center is in the final installation location—not before.
• If the Distribution Center will be anchored to the floor, install appropriate anchor bolts in the mounting holes at the bottom
of the cabinet. Use washers to create a level surface between the mounting areas around the anchor bolts.
• Use extreme caution when removing the bolts securing the Distribution Center to the shipping pallet.
DANGER! LETHAL HIGH VOLTAGE HAZARD!
All wiring must be performed by a qualified electrician, in accordance with the warnings in
this manual and all applicable electrical and safety codes. Incorrect wiring may cause serious
personal injury and property damage.
Wiring Warnings
• All wiring must be performed by a qualified, certified electrician. Know the procedure for disconnecting electricity
in case of an emergency. Do not work alone. Use appropriate protective clothing and tools. Follow all applicable
electrical wiring and safety regulations.
• The Distribution Center contains hazardous high voltages that have the potential to cause personal injury or death from
electric shock.
• The Distribution Center must be suitably grounded according to all applicable electrical wiring regulations.
• De-energize all power sources before installing cables or making electrical connections.
• Use flexible cable of sufficient length to permit Distribution Center servicing.
• Confirm that all cables are marked correctly according to their purpose, polarity and diameter.