Torin TQ22001 Manual Del Propietário página 10

Gato de servicio neumatico/hidraulico
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

3. Pour a teaspoon of good quality, air tool lubricant
into the air supply inlet of the lift control valve.
(See illustration) Connect to air supply and
operate for 3 seconds to evenly distribute
lubricant.
4. Check and that the pump operates smoothly
before putting into service.
5. This product is fitting use standard 1/4" NPT air
fitting. If changing the fitting is required, install a
1/4" NPT fitting of your choice, ensure that thread
tape or compound is used to seal connection.
6. Inspect before each use. Do not use if bent,
broken or cracked components are noted.
OPERATION
RAISING THE JACK
1. Block the vehicle's wheels for lifting stability.
Secure the load to prevent inadvertent shifting
and movement
2. Position the jack near desired lift point.
3. Set the Parking Brake in the vehicle.
4. Refer to the vehicle manufacturer owner's
manual to locate approved lifting points on the
vehicle. Position the jack so that the saddle is
centered and will contact the load lifting point
firmly.
5. Assemble the handle, ensure that spring clips
align with slots.
6. Close the release valve by turning it clockwise
until it is firmly closed.
7. Connect air source to the air supply inlet (26).
8. Close the release valve by turning the handle
knob clockwise until firm resistance is felt.
9
Autogoods "130"
air source
26

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Tq35001

Tabla de contenido