Adjustment Of Stop Ends; Emergency Release - Erreka AXIL Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

OPERATION END-STOP
For the end-stop operation, proceed as follows:
• Bring the shutter in position of maximum opening, then position the mechanical stop A, and shot effect, against the crosshead nut.
• Block the mechanical stop by fastening the bolt with a 13mm key.
• Bring the shutter in position of maximum closing, then position the mechanical stop B (accessory code AAX01), and shot effect, against
the crosshead nut.
• Block the mechanical stop by fastening the bolt with a 13mm key.

EMERGENCY RELEASE

In case of lack of electrical power, or loss of power, bypassing
the motor can unblock the gate:
1. Open the closing cover J located on the front side of the
motor
2. Insert key K in the lock, turn it clockwise and completely open
the plastic access flap
3. Insert key L in the hole and rotate clockwise until end-stop
In order to restore the automation proceed as follows:
1. Turn the key L in counter-clockwise sense until end-stop and
remove it
2. Close the access flap and turn the key K in counter-clockwise
sense
3. Cover the lock with the access flap J
23

Publicidad

Tabla de contenido
loading

Tabla de contenido