ALLMATIC
9.1
Clamping Force Pre-Setting
The clamping force steps are pre-settable in 4 to 11 steps. The set maximum clamping force
can be achieved with a maximum of two revolutions.
1. Pull out clamping force pre-setting device.
2. Turn the clamping force pre-setting device to the required value. The marking must point to
the corresponding number.
ð The clamping force pre-setting device can be turned clockwise and anti-clockwise but
not beyond the zero point.
3. Push clamping force pre-setting device back.
NC8 – 90
Step 1 – 3.5 kN
Step 2 – 6.0 kN
Step 3 – 8.0 kN
Step 4 – 10.5 kN
Step
NC8 – 125 M/L
0
0 kN
1
10 kN
2
20 kN
3
30 kN
4
40 kN
NC8 Series
1
2
3
Step 5 – 13.0 kN
Step 6 – 15.5 kN
Step 7 – 18.0 kN
Step 8 – 20.5 kN
NC8 – 160/200
0 kN
15 kN
30 kN
45 kN
60 kN
Step 9 – 23.0 kN
Step 10 – 25.5 kN
Step 11 – 28.0 kN
NC8 – 200 Heavy - Duty
0 kN
20 kN
40 kN
60 kN
80 kN
Operation | 9
EN
67 / 410