KNOW YOUR GENERATOR
Read the owner's manual and safety rules before operating your generator.
Compare the illustrations with your generator to familiarize yourself with the locations of various controls and
adjustments. Save this manual for future reference.
FuelTank
Circuit Breakers
(AC)
120 Volt AC,
20 Amp
Duplex
Receptacle
120 Volt AC.
20 Amp
Locking
Receptacle
120 Volt AC,
30 Amp
Locking
Receptacle
120/240 Volt AC,
30 Amp Locking
Receptacle
Fuel Shut Off Valve
120/240 Volt AC,
50 Amp Receptacle
Air Filter
top of engine)
Key Switch
Choke
Oil Filter
120 Volt AC, 20 Amp Duplex Receptacle -- Each
supplies electrical power for the operation of 120 Volt
AC, 20 Amp, single phase, 60 Hz electrical lighting,
appliance, tool and motor loads.
120 Volt AC, 20 Amp Locking
Receptacle
--
Supplies electrical power for the operation of 120 Volt
AC, 20 Amp, single phase, 60 Hz electrical lighting,
appliance, tool and motor loads.
120 Volt AC, 30 Amp Locking Receptacle --
Supplies electrical power for the operation of 120 Volt
AC, 30 Amp, single phase, 60 Hz electrical lighting,
appliance, tool and motor loads.
120/240 Volt AC, 30 Amp Locking
Receptacle
--
Supplies electrical power for the operation of
120 and/or 240 Volt AC, 30 Amp, single phase, 60 Hz
electrical lighting, appliance, tool and motor loads.
120/240 Volt AC, 50 Amp Receptacle -- Supplies
electrical power for the operation of 120/240 Volt AC,
single phase, 60 Hz welder or motor loads at
50 Amps.
Air Filter -- Filters intake air as it is drawn into the
engine.
Choke -- Used to start a cold engine.
Circuit Breakers
(AC) -- Each receptacle is provided
with a circuit breaker to protect the generator against
electrical overload. Breakers are "push to reset" type.
Fuel Shut-Off
Valve -- Always have the fuel shut-off
valve closed when engine not running.
Fuel Tank -- Tank holds 10 U.S. gallons of unleaded
gasoline.
Key Switch -- Used to start engine. Always have key
switch in the "Stop" position when not in use.
Oil Filter-
Filters engine oil to prolong engine life.