PROBLEM
Generator suddenly stops
running.
Engine runs erratic; does
not hold a steady RPM.
POTENTIAL CAUSE
1.
Generator is out of fuel.
2.
The low oil shutdown switch
has stopped the engine.
3.
Too much load
4.
If trying 1-3 above does
not solve the problem, the
cause might be a fault in the
generator.
1.
Choke was left in the ON
position.
2.
Dirty air filter
3.
Applied loads may be cycling
on and off
4.
If trying 1-3 above does not
solve the problem, the cause
might be a fault in the generator
TROUBLESHOOTING
1.
Check fuel level (see page 21). Add fuel if
necessary.
2.
Check oil level and add oil if necessary (see pages
26 and 27).
3.
Restart the generator and reduce the load.
4.
Take the generator to your nearest authorized
service dealer.
1.
Move choke to the OFF position (see page 24).
2.
Replace the air filter (see page 28).
3.
As applied loads cycle, changes in engine speed
may occur; this is a normal condition.
4.
Take the generator to your nearest authorized
service dealer.
SOLUTION