Palazzetti Sunny Fire Ecomonoblocco Serie Generalidades - Advertencias - Instalación - Mantenimiento página 36

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

6.6
HOT AIR DELIVERY CONNECTION
This section is dedicated exclusively to models equipped
with heat recovery hood.
If the monoblocco is not equipped with heat recovery
hood, make sure you provide heat recovery grilles in the
hood as shown above.
6.6.1
Connection in counter-hood for single-room
heating
Install the exible pipes for hot air distribution to the outlet
nozzles, above the hood, securing them with the special
clamps. Soundproof the pipes by cladding them with the
insulating material (Fig. 6.10: A-clamps, B- distribution
pipe, C-insulation, D-outlets).
6.7
COUNTER-HOOD
For the realization of the counter-hood, we recommend
the use of plasterboard reproof , becasue it is easy to
work with and because it will keep from overloading with
boards and beams the structure of the monobloc, the
marble architrave and the wood beam which must NOT
act as load-bearing structures
• During realization of the hood it is indispensable to
protect the door sliding frame with nylon covering secured
with adhesive tape. This will keep dust, mortar or foreign
objects from getting stuck between the outlets and the
runners, thus keeping the door itself from sliding. Remove
the protection when work is complete.
• Before carrying out nal assembly, it would be a good
idea to make a smoke test, which means operating the
replace both with the door open and with the door
closed.
B
A
C
D
- 6.10 -

Publicidad

Tabla de contenido
loading

Tabla de contenido