Descargar Imprimir esta página

Noise Risk - IMER COMBI 230 VA Manual De Uso, Mantenimiento Y Recambios

Tronzadora

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

Repairs to the electrical installation must be performed exclusively by
specialised personnel. Use exclusively original IMER spare parts; modi-
ve is required.
Ensure that the contacts of the power plug and plug-switch assembly
As regards disposal of processing waste observe all current legislation
in the country of use.
Although the sawing machine has been manufactured fully in complian-
ce with current regulations, residual risks exist that cannot be eliminated
and involve the use of appropriate individual protection devices. Ade-
the behaviour to be followed.

NOISE RISK

Please be reminded that checking the use of IPDs is delegated to the
employer.
IMER INTERNATIONAL S.p.A.
COMBI 250 VA
-
The motor does not
start when the start
switch is pressed
Cooling water fails
to reach the blade
The blade does
not cut
13
Remedies
Current does not reach
Check the line *
the supply line
The socket and plug
Restore correct
are not connected
connection
properly
The differential switch
Turn the differential
is off
switch on
The power cable from
Change the cable *
the plug to the panel
is cut off
An electric wire inside
Restore the connection *
the motor terminal strip
is cut off
An electric wire inside
Change the switch *
the panel is cut off
The start switch is
Change the switch *
faulty
Low water level in tank Restore the water level
Current fails to reach
Check the pump
the pump
electrical supply *
Pump failure
Change the pump *
Remove the blade
opposite direction to
and reposition it in the
that of rotation
direction shown on the
blade label
Worn blade
Change the blade
GB

Publicidad

loading

Este manual también es adecuado para:

Combi 250 va1188160118816211881631188165