EXTERNAL VIEW AND CONTROLS
Lens cover
1.
Lens focus ring
2.
Battery Pack
3.
Micro-USB connector
4.
Eyeshade
5.
Diopter adjustment ring
6.

DESCRIPTION OF CONTROLS

Button
Device status
Button
Device is off
ON / OFF
Display OFF mode
Device is on
Navigation
Regular (observation)
button
Main menu
UP
Quick menu
Button
Regular (observation)
MENU
Main menu
Quick menu
Navigation
Regular (observation)
button
Main menu
DOWN
Quick menu
Record
Video
button
REC
Photo

USING THE BATTERY PACK

Helion 2 XQ thermal imaging scopes are supplied with a rechargeable Li-Ion Battery Pack IPS7 which allows
operation for up to 9 hours. Please remember to charge the Battery Pack before first use.
CHARGING
Lift the lever (C) of the charging base.
Remove the protective cover from the Battery Pack.
Insert the battery into the charger until it stops, as shown in Fig., lower the lever (C).
Upon installation, a green indicator (D) on the charger will start to glow and begin flashing:
once if the battery charge ranges from 0% to 50%;
twice if the battery charge ranges from 51 and 75%;
three times if the battery charge ranges from 76% to 99%.
If the indicator lights green continuously, the battery is fully charged. You can disconnect it from the charger.
To charge the battery, connect the micro-USB plug of the USB cable to port (E) of the charger.
Connect the plug of the USB cable to the mains adapter.
Plug the mains adapter into a 100-240 V socket and the battery charging process will start.
If the indicator of the charger lights up red continuously upon battery installation, the battery charge level
THERMAL IMAGING SCOPE HELION 2 XQ
Record button REC
7.
Navigation button DOWN
8.
Button MENU
9.
Navigation button UP
10.
Activation / calibration button ON
11.
Lever for Battery Pack
12.
First short press:
Other short presses
Long press:
Power device on
Calibrate the sensor
Turn display off / Power
device off
Turn display on
Calibrate the sensor
Microbolometer calibration
Switch observation modes
Switch colour palettes
Navigation up / right
Change parameters
Enter quick menu
Enter main menu
Confirm selection
Exit submenu without
confirming selection
Switch between quick menu options
/ Exit menu (switch to
observation mode)
Control discrete zoom
PiP on / off
Navigation down / left
Change parameters
Start video recording Pause / resume video
Stop video recording /
recording
Switch to photo mode
Take a photograph
Switch to video mode
4