Status Bar; Stadiametric Rangefinder - Pulsar HELION 2 XQ Serie Manual De Instrucciones

Ocultar thumbs Ver también para HELION 2 XQ Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 30

STATUS BAR

A
The status bar is located in the lower part of the display and shows information on the actual operating status
of the device, including:
Colour palette (shown only if the Black Hot palette is selected)
Observation mode
Calibration mode (in the automatic calibration mode, three seconds before automatic calibration a
countdown timer 00:01 is shown in place of the calibration mode icon).
Current full magnification (for example, 16x)
Microphone
Wi-Fi connection status
Time
Battery charge level (if the device is powered by the Battery Pack) or External battery power indicator
(if the device is powered by an external power supply).
VIDEO RECORDING AND PHOTOGRAPHY
Helion 2 XQ thermal imagers feature video recording and photography of the image being observed to the
internal memory card.
Before using this feature please set the date and time (see the corresponding menu options).
The built-in recorder operates in two modes – VIDEO and PHOTO:
VIDEO MODE. VIDEO RECORDING
The device is in the VIDEO mode upon turning on.
In the top left corner of the display you will see the video icon and the remaining recording time in the format
HH:MM (Hours:Minutes);
12:10.
Start video recording with a short press of the REC (7) button.
Pause video recording with a short press of the REC (7) button.
Resume recording video with a short press of the REC (7) button.
Stop recording video with a long press of the REC (7) button.
When video recording is started the icon disappears and the icon REC and a recording timer in the format
MM:SS (Minutes:Seconds) appears instead; lREC | 00:25.
Video files are saved to the internal memory card after video recording stops.
Switch between modes (Video-> Photo-> Video...) with a long press of the REC (7) button.
PHOTO MODE. PHOTOGRAPHY
Switch to the PHOTO mode with a long press of the REC (7) button.
Take a picture with a short press of the REC (7) button.
The image freezes for 0.5 sec while the photo is saved to the internal memory.
In the top left corner of the display you will see a camera icon
take. If the number is less than 100 the actual number will be shown (i.e. 98) but if more than 100 pictures can
be taken >100 will be displayed next to the icon.
Notes:
you can enter and operate the menu during video recording;
the counter for multimedia files CANNOT BE RESET;
recorded videos and photos are saved to the internal memory card in the format img_xxx.jpg (photos);
video_xxx.mp4 (videos) where xxx is a three-digit counter for videos and photos;
THERMAL IMAGING SCOPE HELION 2 XQ
16x
12:30AM
and the number of pictures you are able to
Warning:
The maximum duration of a recorded file is five minutes. After this time expires, a video is recorded into a
new file. The number of recorded files is limited by the capacity of the device's internal memory;
regularly check the free capacity of the internal memory and move recorded footage to other storage media
to free up space on the internal memory card.
WI-FI FUNCTION
Helion 2 XQ thermal imagers feature a wireless connection option (Wi-Fi) which links them with external
appliances (smartphone, tablet PC).
Activate the main menu by long pressing the М (9) button.
Select the Wi-Fi activation menu option using the UP (10) / DOWN (8) buttons and briefly press the M (9)
button icon to activate the Wi-Fi module.
Wi-Fi operation is shown in the status bar as follows:
Connection Status
Wi-Fi is off
Wi-Fi activated by the user, Wi-Fi in the device is being activated
Wi-Fi is on, no connection with device
Wi-Fi is on, device connected
The device is recognized by an external device as Helion2_XXXX where XXXX are the four last digits of the
serial number.
After entering the password (default: 12345678) on a mobile (see Wi-Fi Setup section of the Main Menu
Functions section of this manual for more information on setting a password) and setting up a connection,
the icon
in the status bar changes to
.

STADIAMETRIC RANGEFINDER

Helion 2 XQ thermal imagers are equipped with a stadiametric rangefinder which allows the user to determine
the distance to an object of a known size with reasonable accuracy.
Select the Stadiametric Rangefinder function with short presses of the M (9) button until the icon
selected.
You will see on the display: measurement bars, icons of three reference
objects and respective distances for the three objects.
There are three pre-set reference objects:
Hare - height 0.3m
Wild boar - height 0.7m
Deer - height 1.7m
Position the lower fixed bar under the object being ranged and by pressing
the UP/ DOWN buttons, move the upper horizontal bar relative to the lower fixed bar until the object fits
entirely between the two bars. The distance to the object is automatically recalculated as you move the upper
line.
If ranging does not take place within 10 seconds, the information disappears from the display.
To select the unit of measurement (Meters or Yards), go to the respective menu option.
Before it appears on the display, a measured distance value is rounded up to 5m for larger values and
rounded down to 1m for smaller values.
Indication on the status bar
is
9

Publicidad

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Helion 2 xq50fHelion 2 xq38f7739777396

Tabla de contenido