Trouble Shooting - Charmglow 810-8640-S Manual Del Propietário

Parrilla electronica gastrónoma de 4 hornillas
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

TROUBLE SHOOTING

Problem:
Burner will not light
Fire at back of grill
Yellow Flames at burner
Flame blows out on "LOW"
Burner does not get hot enough
Grill is Too Hot
No power to control panel
Possible Causes:
1. Check LP cylinder fuel level.
2. Bad electrode spark.
Check to see if the grill will match light.
Electrode or collector may need adjustment.
3. Burner may not be properly seated.
4. Burner may be obstructed.
5. The cylinder valve may be closed.
6. Regulator is not properly seated on cylinder valve.
1. Burner holes may be obstructed. See section on
"Burner Assembly/Maintenance" under Proper Care
and Maintenance.
2. Burner is improperly seated on gas nozzle.
3. Gas connections may be loose.
Leak Check and tighten all connections.
1. Burner is obstructed. See section on
"Burner Assembly/Maintenance" under Proper Care
and Maintenance.
1. Burner holes may be obstructed. See section on
"Burner Assembly/Maintenance" under Proper Care
and Maintenance.
2. Burner is improperly seated on control valve.
1. Flow control device has been activated in regulator.
See Regulator Resetting Procedure under
Connecting LP Cylinder and Hose/Regulator to Grill.
2. Burner holes may be obstructed. See section on
"Burner Assembly/Maintenance" under Proper Care
and Maintenance.
1. Excess grease build-up causing grease fires.
2. Damaged or faulty regulator.
Replace with factory authorized parts.
3. Cook on a lower temperature setting.
1. The control box is not plugged to power supply,
or the control panel is not powered on.
18