Mains terminals and motor terminals may still have dangerous voltage when the
motor is stopped.
If the power cable is damaged, it must be replaced by the technical assistance service
or by qualified personnel, so as to avoid any risk.
3. PUMPED LIQUIDS
The machine has been designed and made for pumping water, free from explosive substances and solid
particles or fibres, with a density of 1000 Kg/m³, a kinematic viscosity of 1mm²/s and non chemically
aggressive liquids. It is possible to use ethylene glycol in a percentage of no more than 30%.
4. APPLICATIONS
EVOPLUS series circulators allow integrated adjustment of the differential pressure which enables the
circulator performance to be adapted to the actual requirements of the system. This determines considerable
energy saving, a greater possibility of control of the system, and reduced noise.
EVOPLUS circulators are designed for the circulation of:
–
water in heating and conditioning systems.
water in industrial water circuits.
–
–
domestic water only for the versions with bronze pump body.
EVOPLUS circulators are self-protected against:
–
Overloads
–
Lack of phase
–
Excess temperature
Over-voltage and under-voltage
–
5. TECHNICAL DATA
Supply voltage
Absorbed power
Maximum current
Grade of protection
Protection class
TF Class
Motor protector
Maximum environment temperature
Liquid temperature
Flow rate
Head
Maximum working pressure
Minimum working pressure
ENGLISH
1x220-240 V (+/-10%), 50/60 Hz
See electrical data plate
See electrical data plate
IPX4
F
TF 110
No external motor protector is needed
40 ºC
-10 ºC ÷ 110 ºC
See Table 1
See Table 1
1.6 MPa
0.1 MPa
26