Shear 30T Shearing Station
Setting the Measurement Stop
The Measurement Stop can be set to repeatedly cut
lengths from 12 to 48 inches. Turn the Measurement
Stop Knob holding down the Extension Arm counter-
clockwise to unlock. Set stop to required cut length by
moving the arm left or right as needed, then retighten the
knob. Raise or Lower the stop such that the workpiece
being cut just makes contact.
7
Greenlee Tools, Inc.
4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070