Page 3
Installation - Replace an Existing Fan
Tools needed
• Phillips screwdriver (recommended)
• Hammer
• Safety glasses
• Pencil
• Tape Measure
• Drywall saw
1
Remove from Packaging
2
Prepare the Housing
1
Loosen 2 blower
screws.
Materials needed
• 4" round metal ducting recommended for best performance. Use of
other ducting is acceptable but may impact performance.
• Roof cap or wall cap (built-in damper recommended)
• Tape to seal duct connections
• Drywall screws, sheet metal screws (optional)
• Electrical wiring and supplies per local code requirements
Punch out
Template from
packaging. See
Step 3.
2
Unplug blower
and remove
blower from
housing.
EZ80N
Installation Guide
n
3
Remove wiring cover.