Page 6
Installation - Replace an Existing Fan
7
Connect Electrical Wiring
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR
INJURY TO PERSONS, OBSERVE THE FOLLOWING:
If unfamiliar with electrical wiring, secure the services of a
qualified person to connect wiring according to all applicable
codes and standards.
Connect house wiring to
wiring plate with UL approved
connector.
Connect wiring as
shown in diagrams.
Attach wiring plate and wiring
cover to inside of housing with
screws provided.
BLK
ON/OFF
SWITCH
BLK
WHT
WHT
120 VAC
LINE IN
GRD
GRD
SWITCH BOX
BLACK
GROUND (green or bare)
WHITE
ON/OFF
SWITCH
(purchase separately)
SWITCH BOX
120 VAC LINE IN
8
Replace Blower
BLK
WHT
M
UNIT
RECEPTACLE
KNOCKOUT
PLATE
Plug blower
into receptacle
and re-install
blower. Tighten
blower screws.
9
Install Grille
Squeeze
1
grille springs
and insert
into slots in
blower.
2
Push grille up against ceiling.
EZ80N
Installation Guide