4
INSTALLATION
4.1
General
The installation must be performed by a professional trained and qualified.
WARNING!
This product is designed for industrial use. In domestic environment this product
may cause radio interference. It is the responsibility of the user to take suitable
precautions.
Note: connect the equipment to the power supply network with a system impedance 0.210 ohm
or lower. If the network impedance is higher, there is a risk of lighting devices present failures.
4.2
Receiving the equipment
At receiving a LHI RECTIFIER remove all the packaging material around the unit and check for
possible damages that could have happened during transport. Any complaints related to
transport damage should be directed to the Transport Company.
NOTE!
In case a LHI RECTIFIER is not installed immediately, keep it in its original
packaging or store it in a dry and well ventilated place.
WARNING-DANGER OF SLOPE!
There is a risk of tipping during transport if the machine is with an inclination of more
than 10°. In this case provide the means of adequate locking.
4.3
Working area
Several facts should be taken into consideration when determining the working place of a
welding machine, in order to have a safe and efficient operation.
An adequate ventilation is needed for the refrigeration of the equipment and for the operator´s
safety. The area should be kept clean.
A circulation corridor should also be left around the LHI RECTIFIER with at least 700mm wide to
provide ventilation and access for operation, preventive maintenance and eventual corrective
maintenance.
The installation of any filter dispositive in the environment restricts the air volume availabe for the
machine refrigeration which can cause overheating to the internal equipment.
All guarantee undertakings from the supplier cease to apply if the customer/user installs any
filter dispositive not authorized by the supplier.
- 26 -