OPI_SMART LIFT 2.30 SL-2.35 SL-2.40 SL - HYMAX S 3000-S3500-S4000_V1.2_DE-EN-FR-ES-IT
Maintenance plan
Check the lift spindle for wear (damage).
Lightly oil the lubrication felt between the spindle centring
and lift nut. Use a runny oil similar to SAE 15 W 40. Nut lubrica-
tion is done with an oil can between the column and spindle
cover panel (removed if needed).
Do not use adhesive oil. Biologically degrading adhesive oil
hardens and can lead to damage of the lift. Normal adhesive
oil negatively impacts the running properties We recommend
using a runny oil, similar to SAE 15W40.
Optical wear measurement:
C atch bar fixation "Safety kit" must be integrated, see
!
Section 9.1.
To check the carrier nut, the cover of the lift spindle must be
removed. There is a carrier nut wear gauge pin integrated
into the carrier plate. This must be flush with the upper edge
of the carrier plate (in the lifting rail, top) - see Figure above.
To a): Changes to manufacturer-specific inspection
1. A wear dimension of 2 mm applies to lifts less than 15 years
old.
2. A wear dimension of 1 mm applies to lifts older than 15
years.
Check the position of the cap-
ture hook.
Lower the lift completely. Re-
move the cover panels and pull
them out upwards. Now the po-
sition of the capture hook can
be checked through the holes in
the lifting rails. These must align
with the latch.
For platforms above serial num-
ber: 379231, the catch can be
additionally checked through
the holes in the lifting rails.
a
Pos.
C
D
E
Openings
in the lifting
rails