3
Technical information
3.1
Technical data
Total weight
Load carrying capacity SMART LIFT 2.30 SL/
Loading a lifting arm
Load distribution
Lift time
Lowering time
Standard operating
voltage
Motor capacity
Motor speed
Noise level LpA
On-site connection
OPI_SMART LIFT 2.30 SL-2.35 SL-2.40 SL - HYMAX S 3000-S3500-S4000_V1.2_DE-EN-FR-ES-IT
SMART LIFT 2.30 SL/
HYMAX S 3000 =
600 kg
SMART LIFT 2.35 SL/
HYMAX S 3500 =
650 kg
SMART LIFT 2.40 SL/
HYMAX S 4000 =
650 kg
HYMAX S 3000 = 3000 kg
SMART LIFT 2.35 SL/
HYMAX S 3500 = 3500 kg
SMART LIFT 2.40 SL/
HYMAX S 4000 = 4000 kg
A single load from only
one lifting arm may not
happen
SMART LIFT 2.30 SL/
HYMAX S 3000
SMART LIFT 2.35 SL/
HYMAX S 3500
max. 2:3 or 3:2 or against
the drive-in direction
SMART LIFT 2.40 SL/
HYMAX S 4000
max. 3:1 or 1:3 or against
the drive-in direction
approx. 40 s (3 t)
approx. 46 s (3,5 t)
approx. 48 s (4 t)
approx. 40 s
3~/N+PE,400 V, 50 Hz
2 x 1,5 kW
1420 rpm
≤ 70 dB
3~/N+PE, 400 V, 50 Hz
With fuse 16 Amp slow
blow
According to VDE regu-
lation
Optional energy set
Important information!
i
The lift is transferred without electrical connec-
tion ready to the provided power supply, after a
check of function and safety. A plug connection
must be provided on-site. This on-site located
connection plug must be located in the im-
mediate vicinity of the lift and may only be set
at a height that can be reached without any
assistance (e.g. ladders). Otherwise a separate,
lockable main switch must be located in the im-
mediate vicinity of the lift that can be reached
without assistance.
3.2
Safety devices
• Safety mechanism for lift nut break
Check the lift nut with the integrated wear dis-
play.
• End switch by the electronic controls
Secure the lift against further extension of the lift
rail upwards or downwards.
• Electronic synchronisation monitoring
Secure against asynchronous running of the lift
rails to each other
• Lifting arm block
Secures the lifting arm against horizontal move-
ment in a lifted condition
• Capture hook
Secure against re-lifting after a lift nut break
• Reversing switch with curtain lock device
Fuse to prevent unauthorized use
Optional:
• Foot bumpers on the lifting arms
Secure against shear and crushing points in the
foot area
• CE-STOP + acoustic warning signal
Secure against shear and crushing points in the
foot area
Pneumatic connection>
for compressed air 6-10
bars
Socket: 220 V/50 Hz
85