ANNUAL CHECK
BGR 232 directive "Windows, doors and main doors with
mechanical operation" is applied. It can be obtained from the
National Insurance Institute for Industrial Accidents of your trade
association or from us on request.
Maintenance operations on windows, doors and main doors
with mechanical operation must be performed only by personnel
authorised by the company, having the necessary experience and
skills (BGR 232).
NOTE: all the technical characteristics indicated refer to a temperature falling beetwen 5°C and +40°C. • Nice reserves the right to
change all the modifications to the product it deems necessary at any time, but keeping the functions and intended use unaltered.
Technical data
Model
Shaft Ø (mm)
Max. torque (Nm)
Rated torque (Nm)
Output rpm
Motor power (kW)
Limit switch rpm
Working voltage (V/Hz)
Duty Cycle
Connection cable (no. x mm 2 )
Operating temperature (°C)
Noise dB(A)
Protection rating (IP)
Weight (kg)
Model
Shaft Ø (mm)
Max. torque (Nm)
Rated torque (Nm)
Output rpm
Motor power (kW)
Limit switch rpm
Working voltage (V/Hz)
Duty Cycle
Connection cable (no. x mm 2 )
Operating temperature (°C)
Noise dB(A)
Protection rating (IP)
Weight (kg)
*
These models are not tested by TÜV-Nord
6 – English
TECHNICAL SPECIFICATIONS
RDF-
140-20
220-15*
30
140
220
120
200
20
15
0.55
1.1
15
1020
12.4
22
RDF-
850-10
1100-10
1400-7*
55
850
1100
1400
700
950
1250
10
10
2.2
2.2
2.2
1040
1040
1040
51.7
51.9
Information for whoever carries out the checks
Gearmotor:
The mechanism is maintenancefree and it is provided with
permanent lubrication. Absolutely no rust must form on the output
shaft.
Fixings:
Make sure that the fixing screws are all in the correct position and
in perfect condition.
Balancing by weights (e.g. in the sectional main doors):
The door must be balanced in all the positions (see the door
assembly instructions) when balancing is done with weights
according to the procedures prescribed by the standards.
Brake (if present):
During the annual check perfect brake operation is to be ascertained.
In the case of heavy wear of the brake pads, it is necessary to
replace the complete brake. Before replacement, disconnect the
cables connected to the electric card.
290-15*
380-15
290
380
250
360
15
15
1.1
1.5
1020
1020
3x230 V / 3x400 V 50 Hz
S 3 60%
5 x 1.5
5 ÷ +40
<70
IP 54
24
28.9
250-24*
350-24
500-24*
40
250
350
230
310
7
24
24
1.1
1.5
1040
1040
3x230 V / 3x400 V 50 Hz
S 3 60%
5 x 1.5
5 ÷ +40
<70
IP 54
58
24.1
29.2
450-15
550-12
40
450
550
400
450
15
12
1.5
1.5
1020
10
27.7
27.7
750-24*
950-24*
55
500
750
950
450
650
850
24
24
24
2.2
2.2
3
1040
1040
1040
32.7
51.9
61
750-9,5
750
700
9.5
1.5
40
35
1250-24*
1400-24*
1250
1400
1100
1250
24
24
4
5.5
1040
1040
63
65