14. DUCT CONNECTION (VERTICAL DISCHARGE ONLY)
1. Plug hood power cord into the outlet.
2. Slide the duct over the adapter/damper on the hood.
3. Use metal foil duct tape to seal the joint.
NOTE: If a transition to 7" or 8" round duct is used (not included), it is recommended to
place it at least 18" away from the adapter/damper.
HJ0190
15. PREPARE DECORATIVE FLUE
Remove protective plastic film covering the lower flue only.
Peel off both corners at the top of the upper flue (note that upper part has one hole on left and right
sides; see illustration on the right).
Position the lower flue rear notches down.
Gently slide upper flue inside lower flue.
Both lower and upper flues are included with the hood, but for a 10-foot ceiling, discard the provided
upper flue and use the optional flue extension model AEWCB3SB (sold separately).