Please read and save this
guide
Thank you for choosing Electrolux, the premium
brand in home appliances. These Installation
Instructions are part of our commitment to
customer satisfaction and product quality
throughout the life of your new appliance.
Exhaust Venting
Free-flowing, clear of lint buildup
4 inch (102 mm) rigid or semi-rigid ducting
of minimal length and turns
NO foil or plastic venting material
Approved vent hood exhausted to
outdoors
Leveling
Dryer is level, side-to-side and front-to-
back
Cabinet is sitting solid on all corners
Gas Supply (Gas Dryer)
Manual shutoff valve present in supply
All connections sealed with approved
sealer and wrench tight
Conversion kit for LP system
Gas supply turned on
No leaks present at all connections -
check with soapy water, NEVER check with
flame
Tools and materials needed for installation:
Adjustable
Phillips, straight, &
pliers
square bit screwdrivers
or
Pipe wrench
LP-resistant
for gas
thread tape
supply
(for natural gas
or LP supply)
4 inch rigid metal or
4 inch, rigid metal or
semi-rigid metal exhaust duct work
½" NPT union flare
4 in.
gas line
adapters (x2) and
(10.2 cm)
shutoff valve
flexible gas supply line
clamp
(gas dryer)
(gas dryer)
Installation Requirements
Installation Checklist
Adjustable
Optional universal
wrench
accessory
wrench
or
Carpenter's level
External
vent hood
3-wire or 4-wire
240 volt cord kit
(electric dryer)
Metal foil tape
(not duct tape)
Questions?
For toll-free telephone support in the U.S.:
1-877-4ELECTROLUX (1-877-435-3287) and in
Canada: 1-800-265-8352.
For online support and product information visit
www.electroluxappliances.com.
240v Electric Supply (Electric Dryer)
Approved NEMA 10-30 or 14-30 service
cord with all screws tight on terminal
block
Approved strain relief installed
Terminal access cover installed before
initial operation
Door Reversal
Follow detailed instructions in this guide
Test hinge and latch for function
Electrical Power
House power turned on
Dryer plugged in
Final Checks
Installation Instructions and Use and
Care Guide read thoroughly
Door latches and drum tumbles when
cycle starts
Registration card sent in
WARNING
FIRE HAZARD
● Failure to follow safety warnings exactly
could result in serious injury, death, or
property damage.
● Do not install a booster fan in dryer exhaust
duct.
● Install all clothes dryers in accordance with
the installation instructions in this manual.
3