Voltage supply

External supply
The communication module is externally supplied with voltage via the DeviceNet cable at
the 5−pole plug connector (X225).
)
Note!
Use a safely separated power supply unit ("SELV"/"PELV") according to EN
61800−5−1.
ƒ The external voltage supply of the communication module is always required.
ƒ Communication with a standard device which is separated from the mains is not
possible.
Terminal data
Terminal
Cable colour
V+
Red
V−
black
Type
Electrical connection
Possible connections
Tightening torque
Stripping length
EDK94AYCDN DE/EN/FR/ES/IT 4.0
Description
External voltage supply
l
U = +24 V DC
l
I
= 170 mA
max
Reference potential for external voltage supply
Values
Plug connector with double screw connection
rigid:
2.5 mm
flexible:
without wire end ferrule
2.5 mm
with wire end ferrule, without plastic sleeve
2.5 mm
with wire end ferrule, with plastic sleeve
2.5 mm
0.5 ... 0.6 Nm (4.4 ... 5.3 lb−in)
7 mm
l
Electrical installation
Voltage supply
2
(AWG 14)
2
(AWG 14)
2
(AWG 14)
2
(AWG 14)
6
39