CUSTOMER RESPONSIBILITIES

Check Safety Valve
Drain Tank
Air Filter
Air compressor pump
intake and exhaust valves
1- more frequent in dusty or humid conditions
cycles automatically when power
is on. When servicing, you may
be exposed to voltage sources,
compressed air, or moving parts.
Before servicing unit unplug or
disconnect electrical supply to
the air compressor, bleed tank
of pressure, and allow the air
compressor to cool.
To ensure efficient operation and lon-
ger life of the air compressor, a routine
maintenance schedule should be pre-
pared and followed. The above routine
maintenance schedule is geared to
an air compressor in a normal work-
ing environment operating on a daily
basis. If necessary, the schedule
should be modified to suit the condi-
tions under which your air compressor
is used. The modifications will depend
upon the hours of operation and the
working environment. Compressors
in an extremely dirty and/or hostile
environment will require a greater fre-
quency of all maintenance checks.
NOTE: See "Operation" section for
the location of controls.
TO CHECK SAFETY VALVE
does not work properly, over-
pressurization may occur, causing
air tank rupture or an explosion.
D21683

MAINTENANCE

Before
each
use
Risk of Unsafe
Operation. Unit
Risk of Bursting.
If the safety valve
Daily
Every
or after
100
each
hours
use
wear certified safety equipment: ANSI
Z87.1 eye protection (CAN/CSA Z94.3)
with side shields
1.
Before starting compressor, pull
the ring on the safety valve to
make sure that the safety valve
operates freely. If the valve
is stuck or does not operate
smoothly, it must be replaced with
the same type of valve.
TO DRAIN TANK
from noise. Air tanks contain high
pressure air. Keep face and other
body parts away from outlet of drain.
Use safety glasses when draining
as debris can be kicked up into
face. Use ear protection (ANSI S12.6
(S3.19) hearing protection) as air flow
noise is loud when draining.
NOTE: All compressed air systems
generate condensate that accumulates
in any drain point (e.g., tanks, filter, after-
coolers, dryers). This condensate con-
tains lubricating oil and/or substances
which may be regulated and must be
disposed of in accordance with local,
state, and federal laws and regulations.
1.
Set the On/Auto/Off lever to "Off"
and unplug unit.
2.
Pull the regulator knob out and
turn counterclockwise to set the
outlet pressure to zero.
14- ENG
Yearly
1
Risk from Flying
Objects. Always
Risk of Unsafe
Operation. Risk