Installation; Wall Mounting - Resol Datalogger DL3 Manual Abreviado

Ocultar thumbs Ver también para Datalogger DL3:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

4

Installation

ATTENTION!
ESD damage!
Electrostatic discharge can lead to damage to electronic com-
ponents!
Î Take care to discharge properly before touching the
inside of the device. To do so, touch a grounded sur-
face such as a radiator or tap!
ATTENTION!
Short circuit!
A short circuit can lead to damage to electronic components!
Î Close the housing before establishing the mains con-
nection!
Do not use the device if it is visibly damaged!
Initial installation must be effected by the system installer or qualified personnel
named by the system installer.
4.1

Wall mounting

The unit must only be located in dry interior rooms. It is not suitable for installation
in hazardous locations and should be protected against electromagnetic fields.
Please pay attention to separate routing of sensor cables and mains cables.
Î Choose a mounting location.
Î Unscrew the crosshead screw from the cover and remove the cover.
Î Mark the upper fastening point on the wall. Drill and fasten the enclosed wall
plug and screw leaving the head protruding.
Î Hang the housing from the upper fastening point and mark the lower fastening
points (centres 180 mm)
Î Drill 2 holes (Ø 6 mm) and insert the wall plugs.
Î Fasten the housing to the wall with the lower fastening screw and tighten.
Î Carry out the electrical connection according to the terminal allocation.
Î Reattach the cover and fasten it using the crosshead screws included.
24
Crosshead
screw
Cable conduits with
strain relief
Upper fastening
180
180
208
Lower fastening
Cover
In order to run cables through
the cable glands, break off the
corresponding flaps!
180
180
208

Publicidad

Tabla de contenido
loading

Tabla de contenido