Installation - Campbell Hausfeld VT639100 Manual De Instrucciones Y Lista De Piezas

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Installation

Disconnect, tag and lock out
power source, then release
all pressure from the system
before attempting to install, service,
relocate or perform any maintenance.
LOCATION
This compressor is not intended for
outdoor installation.
It is extremely important to install the compressor in a clean,
well ventilated area where the surrounding air temperature
will not be more than 100°F.
Unbolt the unit from the shipping skid (see Figure 2). Remove
the unit from the skid. This requires at least two people - one
person to walk the unit off the skid and one to help maintain
balance so the unit does not topple. Place the unit where you
plan to install it (at least 18 inches from any wall or surface).
Provide a minimum clearance of 18 inches between the
compressor flywheel or fan to the wall and ensure clear access
to the drain valve to facilitate condensate drainage.
Do not locate the compressor air inlet near steam, paint spray,
sandblast areas or any other source of contamination.
MOUNTING
Never use the wood shipping skids for
mounting the compressor.
FLOOR MOUNTING
The compressor feet MUST be bolted to a flat, even, concrete
floor or separate concrete foundation. Vibration isolators
must be used between the tank leg and the floor (part
number MP344500AJ, available separately). Do not draw bolts
tight. Allow the pads to absorb vibrations. A flexible coupling
should be installed between the tank and service piping.
This compressor is extremely top heavy.
The unit must be bolted to the fl oor
with isolation pads before operating to prevent equipment
damage, injury or death.
Never install a shut-off valve between the
compressor pump and the tank. Personal
injury and/or equipment damage may occur.
1. Place pre-drilled vibration pads (sold separately) under
each foot to avoid unnecessary vibration which could
damage the unit.
Using the mounting holes and the holes of the vibration
pads as a guide, drill holes into concrete using a 3/8 inch
masonry bit. Holes drilled must be at least 5 inches into
the concrete (see Figure 3).
Hardware Required for Installation (not included)
Concrete wedge anchors
Figure 2
Figure 3
5
Vibration isolation set
(3 metal plates and
6 rubber pads)
www.campbellhausfeld.com
VT639100
Strain relief