Wire the Light Control
WARNING: Turn power off at circuit breaker or
fuse. Place tape over circuit breaker switch and
verify power is off at the fixture.
1. Remove the existing light fixture.
2. Install mounting strap to junction box using screws
appropriate for your junction box.
3. The plastic hanger can be used to hold the fixture
while wiring. The small end of the plastic hanger
can be threaded through the hole in the center of
the cover plate. The small end then goes into one
of the slots on the mounting strap.
4. Thread all fixture wires through the large holes in
the gasket as shown.
5. Connect the junction box wires to the light fixture
wires as shown. Twist together and secure with
wire connectors.
CAUTION: Do not cut any wires with factory
installed wire connectors.
White to White
Mounting Strap
Gasket
Black to Black
Connect green or bare copper wire(s) in the fixture
to green ground screw and ground wire in junc-
tion box. Note: All ground wires shown as green
in above illustration.
204057-01
Mount the Light Control
1. Place the mounting bolt through the front of the
junction box cover. Push the small gasket hole over
the mounting bolt.
2. Make sure the wire connectors and wires are inside
the junction box. Align the mounting bolt with the
center hole in the mounting strap. Secure the fixture
to the mounting strap.
3. Push the rubber plug firmly into place.
4. If not installed on a weatherproof box, caulk the
wall plate and mounting surface with silicone.
5. Adjust the lamp heads by loosening the lock nuts
but do not rotate the lamp heads more than 180°
from the factory setting.The locking screw should be
on top and the lamp heads should be horizontal.
3
Mounting Bolt
Rubber Plug
Push the rubber plug
over the mounting screw.
Locking Screw
Keep lamp heads at least 1"
(25 mm) from the sensor.