THERMEx Le Mans I Manual Del Usuario página 214

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

EN 
ANTI GREASE FILTER CLEANING ALARM
Every 30 hours' operation, when aspiration is switched off, letter "G" will light up on the
display for 30 seconds warning that anti grease filter cleaning is necessary.
To reset the timer press T3 for 5 seconds while aspiration is switched off, otherwise the
device will give the same warning the next time aspiration is switched off.
CHARCOAL FILTERS REPLACING ALARM
Every 120 hours' operation, when the hood is switched off, the display will show "S" for
30 seconds reminding the substitution of the charcoal filters (when installed). To reset
the timer, keep the T3 key pressed for 5 seconds with aspiration switched off, otherwise
the device will give the same warning the next time aspiration is switched off.
The warning will be reported even if the hood is not in filtering mode: in this case proceed
with the ordinary cleaning of the anti-grease filter and reset the warning.
PRESENCE OF LIQUIDS INSIDE THE DEVICE ALARM
The device is equipped with an electronic internal sensor that immediately switches the
aspiration off in case of condensation or excess liquids resulting from accidental fall
through the flaps. The display will show "8" blinking for one minute.
The system is operating even when the device is switched off.
To reset the warning and switch the device on it is absolutely necessary to discharge the
liquids.
CAUTION! Electrically disconnect the mains plug before any service
operation. (fig.1-2 chapter WARNINGS)
To discharge the liquids unscrew the knob (fig.37-X) and open the drain cover.
It is recommended to place the container for collecting liquids at the arrow.
Fig. 5.8
67 

Publicidad

Tabla de contenido
loading

Tabla de contenido