Placing Tool In Service - Ingersoll Rand MULTI–VANE 2X–EU Serie Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 21
LUBRICATION
Ingersoll–Rand No. 50
Always use an air line lubricator with this tool.
We recommend the following Filter–Lubricator–Regulator
Unit:
No. C28–C4–FKG0
Before starting the tool and after each eight hours of
operation, unless the air line lubricator is used, after
detaching the air hose, unscrew the Oil Chamber Plug and fill
the chamber in the Backhead with Ingersoll–Rand
No. 50 Oil.
After each forty–eight hours of operation, or as experience
indicates, inject about 1 to 2 cc of Ingersoll–Rand No. 28
Grease into the Grease Fitting.
Occasionally, inject 2 to 3 drops of Ingersoll–Rand No. 50 Oil
into the oil hole in the Throttle Sleeve.

PLACING TOOL IN SERVICE

Ingersoll–Rand No. 28
MAIN LINES 3 TIMES
AIR TOOL INLET SIZE
TO
AIR
SYSTEM
TO
AIR
TOOL
LUBRICATOR
REGULATOR
BRANCH LINE 2 TIMES
AIR TOOL INLET SIZE
DRAIN REGULARLY
3
FILTER
COMPRESSOR
(Dwg. TPD905–1)

Publicidad

Tabla de contenido
loading

Tabla de contenido