Descargar Imprimir esta página

Smeg IS7099X90 Instrucciones Para Instalación Y Uso página 10

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 17
ENGLISH
DESCRIPTION
This hood has been designed to offer the very best performance in most operating conditions. At average speed
in fact, an excellent ratio is achieved between extracted air flow, low power consumption and noise. Use higher
speeds in case of emissions of large quantities of cooking vapours, including for prolonged periods of time.
The unit can be found in filtering hoods, ducting hoods or in hoods with an outside motor.
In the Filtering version the air and the kitchen fumes that are conveyed by the apparatus are depurated
by the charcoal filter and put back into the room through the small grilles of the ventilation flue (Fig. 1). ATTENTION:
When using the filtering version, a charcoal filter and an air baffle (Fig. 1A) must be used, which placed at the
top of the structure, allows the air to recycle back into the room.
In the Ducting version, cooking vapours and odours are conveyed straight outside by a disposal duct which
passes through the ceiling (Fig. 2). In the hoods with an outside motor (Fig. 3), a vacuum suction unit must
be connected; this exhaust will operate separately, conveying the exhaust air through the unit. Only use vacuum
units suggested in the original catalogue.
Warning: Failure to install the screws or fixing device in accordance with these instructions may result in
electrical hazards.
INSTALLATION
ATTENTION: Three people are required for proper installation; the unit should be installed by a qualified operator.
Also follow carefully each step of the assembly instructions, and once installation has been completed, make sure
that the hood is firmly secured in place.
To facilitate installation, before starting remove the grease filters: press inward on the clamp at the handle and pull
the filter downward (Fig. 4).
For assembling it is essential to: – Prepare the connection to the mains within the telescopic flue. – If your unit is
installed in a ducting hood or in a hood with outside motor, prepare the air exhaust hole.
When installing ducting hoods and hoods with external motor, to achieve the best possible conditions use an air
exhaust pipe that : is as short as possible, has a minimum of curves (maximum angle: 90°), is made of a material that
complies with the standards (which vary from nation to nation) and is smooth on the inside. It is also advisable to avoid
any drastic changes in pipe section (diameter: 150 mm).
ASSEMBLING - Using the special drilling template, drill the holes for fixing to the ceiling on the vertical side of your
hob. Carefully observe all the indications for final positioning of the apparatus. Take into account that one of the template
axes must correspond to the axis of the hood controls. Fix the bracket to the ceiling using the screws and screw anchors
provided (Fig. 5). Be careful, because the position of the bracket determines the final position of the apparatus: the side
with the slot B corresponds to the side opposite the commands. Assemble the plate of the electrical system fixing it with
2 screws and 2 metal washers (Fig. 6).
Ducting version and version with an external motor: Fix the telescopic structure to the bracket by means of 4 screws
(provided), running the air evacuation pipe through the telescopic structure and the electric power cable through the special
hole in the bracket (Fig. 7). Adjust the height of the telescopic structure by means of the four retaining screws C (Fig.8),
taking into account that the height of the hood is 80 mm and that the distance between the hood and the hob must be
at least 650 mm (Fig. 9). Take the upper pipe (with the round slots) and fit it on the telescopic structure with the slots
facing downwards; fit the pipe to the bracket with 2 screws (Fig. 10). Take the lower pipe and fit it in the same manner
as before; slide it to the top and stop it in that position using a screw inserted in the hole of the upper pipe as a catch
(Fig. 11). Take the flange with the metal valve (Fig. 12H) and assemble it onto the opening of the hood for air venting,
pressing slightly. Fit the hood to the telescopic structure by means of 4 screws (provided) – Fig. 13.
Through openings D (Fig. 13) fix the air evacuation pipe to flange H. Only for models with external motor (Fig. 14): connect
the hood to the external motor using the special terminal block: remove wire clamp A and lid B from the wiring junction
box; fix the connecting wire of the external motor to terminal C; then replace wire clamp A and lid B on the wiring junction
box; the other end of the wire is secured to the terminal block on the external motor.
Make the electrical connection by means of the power cable. Remove the screw used as catch and slide the lower pipe
downwards, placing it gently on the apparatus. Installation is now complete and the anti-grease filters can be reassembled.
Filtering version: Fix the telescopic structure to the bracket by means of 4 screws (provided), running the electric power
cable through the special hole in the bracket (Fig. 7). Adjust the height of the telescopic structure by means of the four
retaining screws C (Fig. 8), taking into account that the height of the hood is 80 mm and that the distance between the
hood and the hob must be at least 650 mm (Fig. 9). Insert the air baffle (F) in the structure (Fig.15). Through the openings
E (Fig.16), fit the flange (G) to the baffle (F) locking it with a turning movement. Fix a flexible pipe to the flange (G) for
air evacuation (Fig. 16). Take the upper pipe (with the round slots) and fit it on the telescopic structure with the slots facing
upwards; fit the pipe to the bracket with 2 screws (Fig. 17). Take the lower pipe and fit it in the same manner as before;
slide it to the top and stop it in that position using a screw inserted in the hole of the upper pipe as a catch (Fig. 11).
Take the flange (Fig. 18H) with the metal valve and assemble it onto the air venting opening of the hood, pressing slightly.
Fit the hood to the telescopic structure by means of 4 screws (provided) – Fig. 19.
Fix the air evacuation pipe onto the reduction (L). Make the electrical connection by means of the power cable. Remove
the screw used as catch and slide the lower pipe downwards, placing it gently on the apparatus. Install the charcoal filter

Publicidad