AIR MASTER SERIES
RETROFIT KIT
Quincy Compressor offers the following retrofit kits
for Emglo K and KU Contractor compressor units.
Retrofit Kits
Quincy Part
Number
115580K001
1.5 h.p. electric motor driven
115580K002
2 h.p. electric motor driven
115580K003
5.5 h.p. gasoline engine driven
Each kit inlcudes:
· Air Master QTS Series basic compressor
(pump)
· belt guard assembly
· relief valve / check valve assembly
(pre-assembled)
· drive belt
· drive pulley
· maintenance decals
· retrofit instructions
· parts / instruction manual.
Air Master Series
50325-100, January 2002
Description
RETROFIT INSTRUCTIONS
Retrofitting an Emglo K or KU Contractor
with an Air Master QTS-3 Basic Com-
pressor
These instructions explain how to retrofit an Air
Master QTS Series basic compressor (pump) as a
replacement for the basic compressor (pump) on an
Emglo K or KU Contractor compressor unit.
It is the responsibility of the installing technician to
read, understand and follow these instructions.
Should questions arise, consult with an authorized
Quincy Distributor or call Quincy Compressor at
217-277-0270.

Stopping for Maintenance

The following procedures must be followed before
retrofitting the Quincy Compressor.
Step 1
Per O.S.H.A. regulation 1910.147: the Con-
trol of Hazardous Energy Source (Lockout/
Tagout), disconnect the compressor unit
from the power source and lockout the
connection to the source. Display a sign in
clear view stating that the compressor is
being serviced.
WARNING !
Never assume a compressor is safe to work on just
because it is not operating. Lockout and tagout per
O.S.H.A. regulation 1910.147.
Step 2
Wait for the unit to cool before starting to
service. (Temperatures of 125° F can burn
skin. Some surface temperatures exceed
350° F when the compressor is operating)
Step 3
Bleed all pressure from the tank. Open the
tank pressure relief valve to verify that the
system has been fully depressurized. Never
remove a plug to relieve the pressure!
Step 4
Open the manual drain valve in the tank.
Step 5
Inspect all components for damage and
replace any items not in proper working
order. Check with an authorized dealer for
motor or engine replacement parts. Never
attempt to repair a tank!