Kübler CODIX 521 Instrucciones De Puesta En Servicio página 10

Contadores indicadores electrónicos
Ocultar thumbs Ver también para CODIX 521:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

3. Programming routine
The first menu item is the selection of the basic
operating mode, which determines the functions
of the device.
Operating mode pulse counter.
Continued in point 4. of CODIX
521 on page 2
Operating mode frequency
meter. Continued in point 4. of
CODIX 522 on page 4
Operating mode time meter.
Continued in point 4. of CODIX
523 on page 6
Pulse counter/Position indicator
CODIX 521
(CODIX 524: Operating mode pulse counter)
1. Description
• 6-digit display counter with SET/RESET-func-
tion
• Red LED display, character height 8 mm
• Display range from -199 999 to 999 999
• Leading zeros suppression
• Programming via two setting keys on the front
side
• During programming, the display guides the
user with text prompts
• Counter operating modes:
Count input INP A + count direction input
INP B (Cnt.Dir)
Differential count INP A – INP B (up.dn)
Totalising INP A + INP B (up.up)
Count Up/Down INP A 90° INP B x 1 (quAd)
Count Up/Down INP A 90° INP B x 2 (quAd2)
Count Up/Down INP A 90° INP B x 4 (quAd4)
• Optional optocoupler output
2. Inputs
INP A
Dynamic count input.
INP B
Dynamic count input.
2
SET/RESET
Dynamic SET/RESET input. Linked in parallel to
the red SET/RESET key. Resets the counter to
the predefined setting value.
3. Optocoupler output
Active if count value < 0. Simple preset counter
can be realized, when using subtract mode.
4. Programming routine
The programmable parameters of the device are
described below, in the order in which they can
be set. The device is fully programmed after one
pass of the routine.
The first values stated correspond to the factor
settings
4.1 Polarity of the inputs
npn: switching for 0 V
pnp: switching for +U
4.2 Switching on the 30 Hz filter
(INP A, INP B)
The filter provides input damp-
ing*
30 Hz filter off (f
30 Hz filter on
4.3 Input mode
Count input and count direc-
tion input
INP A: Count input
INP B: Count direction input
Differential input
INP A: count input adding
INP B: count input subtracting
Totalising
INP A: count input adding
INP B: count input adding
Quadrature input
INP A: count input 0°
INP B: count input 90°
(optional)
B
)
max

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Codix 522Codix 523Codix 524

Tabla de contenido