IMPORTANT SAFETY INSTRUCTIONS
DANGER
A person who has not read and
understood all operating
Instructions is not qualified to
operate this product.
DANGER
•
Do not immerse splice connection in liquid.
•
Keep volatile or combustible material away from
splice connection when in use.
•
Use splice connection kit only in approved
locations.
•
Keep sharp metal objects away from splice
connection.
Failure to observe these warnings may result in electric
shock, risk of fire, and personal injury.
WARNING
End-User Must Comply to the Following:
•
Only qualified personnel are allowed to connect
electrical wiring.
•
Disconnect all supply power at the source before
making any power connections.
•
All electrical wiring must follow local electrical
codes and highly recommend following NEC
Article 427.
•
The person who performs the final installation /
wiring must be qualified for this work.
•
The end-user is responsible for providing a
suitable disconnecting device.
•
The end-user is responsible for providing suitable
electrical protection device. It is highly
recommended that a ground fault circuit breaker
be used.
Failure to observe these warnings may result in personal
injury or damage to the heater.
®
© BriskHeat
Corporation. All rights reserved.
JHS-GET
Low-Profile Inline Splice Connection Kit
AGENCY APPROVALS
For SLCBL -BP, -BF Series only
Class I, Div. 2 , Groups A, B, C, D
Class II, Div. 2 , Groups E, F, G
Class III
Approvals valid only when installed in accordance with
all applicable instructions, codes, and regulations.
CAUTION
•
Inspect all components before use.
•
Do not use splice connection kit if any component
is damaged.
•
Do not repair a damaged or faulty components.
•
Do not crush or apply severe physical stress on
any component of system.
•
Unit must be mounted away from vibration,
impacts, water and corrosive gases.
•
Do not operate splice connection kit above rated
temperature value.
•
Fasten splice connection kit to the pipe using
approved methods only.
Failure to observe these warnings may result in personal
injury or damage to the heater.
3
PRIOR TO INSTALLATION
Description
•
The JHS-GET is designed for use with BriskHeat SLCBL / SLMCBL / SLHCBL series
heating cables in ordinary locations only.
•
The JHS-GET kit is approved by CSA for use in hazardous area locations with SLCBL
series heating cable only.
•
The JHS-GET should be installed on pipe under insulation and/or cladding.
•
The JHS-GET is rated NEMA 4X.
Specifications
•
Maximum current: 32A
•
Voltage: 110-120V, 208-277V
•
Maximum Continuous Exposure Temperature (T5): 212°F (100°C)
Tools and Materials Required
•
Wire cutter
•
Screwdriver
•
Needle-nose pliers
KIT INCLUDES
Item
Qty
Description
A
1
Main box
B
2
Pressure Seal Ends
C
2
Grommets
D
2
Gaskets for Main Box
E
2
Covers for Main Box
F
1
Label
WARNING
•
This component is an electrical device that must be installed correctly to ensure proper
operation and to prevent shock or fire. Read these important warnings and carefully follow
all of the installation instructions.
•
To minimize the danger of fire from sustained electrical arcing if the heating cable is
damaged or improperly installed, and to comply with the requirements of BriskHeat
certifications, and National Electrical Codes, Groundfault equipment protection must be
used. Arcing may not be stopped by conventional circuit breakers.
•
Component approvals and performance are based on the use of BriskHeat specified parts
only. Do not use substitute parts or vinyl electrical tape.
•
The black heating cable core is conductive and can short. It must be properly insulated and
kept dry.
•
Damaged bus wires can overheat or short. Do not break bus wire strands when scoring the
jacket and core.
•
Keep components and heating cable ends dry before and during installation.
•
Bus wires will short if they contact each other. Keep bus wires separated.
•
Use only fire-resistant insulation materials, such as fiberglass wrap or flame-retardant foam.
®
© BriskHeat
Corporation. All rights reserved.
JHS-GET
Low-Profile Inline Splice Connection Kit
•
Utility knife / Razor blade
•
Fiberglass Tape (PSAT36A)
•
JHS-GET low-profile inline splice
connection kit
B
C
A
SPLICE
ELECTRIC TRACED
D
E
F
4