ABIPLAS
CUT
NOTICE
• The ABIPLAS
• As the ABIPLAS
operating instructions of the welding components, such as the robot control system, must
be observed during operation.
• Check the actual gas flow on the measuring instruments or by closing and opening the
corresponding gas outlet openings on the torch.
8 Putting out of operation
NOTICE
• When putting the system out of operation, ensure that the procedures for switching off
each of the welding system components are observed.
1 Switch off the cutting power source.
2 Close the compressed air feed.
9 Maintenance and cleaning
Scheduled maintenance and cleaning are prerequisites for a long service life and trouble-free
operation.
DANGER
Risk of injury due to unexpected start-up
The following instructions must be adhered to throughout all maintenance, servicing,
assembly, disassembly and repair work:
• Switch off the power source.
• Close the gas supply.
• Close the compressed air supply.
• Disconnect all electrical connections.
DANGER
Electric shock
Dangerous voltage due to defective cables.
• Check all live cables and connections for proper installation and damage.
• Replace any damaged, deformed or worn parts.
BAL.0099 • 2018-11-08
®
CUT welding torch may only be operated by qualified personnel.
®
CUT welding torches are integrated into a welding system, the
8 Putting out of operation
EN - 21