English; Working Principle - Johnson Pump SPX Viking Power 16 Manual De Instrucciones

Ocultar thumbs Ver también para SPX Viking Power 16:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 17
> English
Viking Power 16 mounted to DC motor 12/24 V
Please follow all instructions before attempting an installation.
Typical applications
The Viking Power 16 is a single diaphragm DC-
pump. This pump is the ideal choice for shower
drain, waste water and bilge pumping. Its compact
design and flexible orientation give a very adapt-
able mounting and installation in the boat.
Model number
Viking Power 16 12V 10-13350-03
Viking Power 16 24V 10-13350-04
Features
• 16 L/min (4.2 GPM) at open flow
• 15 L/min (4.0 GPM) at 0.1 bar pressure
• Compact and flexible configuration and installa-
tion
• Quick disconnect fittings (1" or ¾" straight hose
connectors included. 90° as accessory.
• Quiet operation
• Smooth flowing
• Self priming to 3 m (10 feet)
• Pump head can be rotated 360°
• Three alternatives to motor orientation
• Dry running without damage
• No filter required
• Ball-bearing supported transmission
• Low power consumption (30W)
• Meets ISO15083 Small Craft Bilge Pump stand-
ard for boats up to 12 m/40 feet

Working principle

Single-chamber, self-priming diaphragm pump. To
obtain good self-prming ability and a filter-less so-
lution, the pump is designed with a large single dia-
phragm and a long stroke. This way a lot of water is
pushed through the valves in each stroke and any
debris is flushed through.
6
Technical description
Body:
Nylon
Valves:
Nitrile
Diaphragm:
Reinforced nitrile
Connection: K lickTite™ XL connectors
1" or ¾" straight hose connec-
tors included. 90° as accessory
Fasteners:
Stainless steel
Fot:
Painted zink plated steel
Max. head:
3 meters (10 feet)
Max.
suction lift:
3 meters (10 feet)
Max head
& lift:
4 meters (13 feet)
Motor:
30 W at 1 m head
12/24 V DC (with built-in
thermal protection)
Fuse size:
8 A – 12V / 4 A – 24V
The pump is CE marked according to the following
standards:
• EN55014-1:2000/Radio disturbance
• EN55014-2:1997/Radio disturbance
• ISO8846: Small Craft – Electrical devices – Pro-
tection against ignition of surrounding flammable
gases
• ISO8849:2003/ Small craft – Electrically oper-
ated bilge pumps
• ISO10133: 2001/Small Craft – Electrical systems
– Extra-low voltage DC installations
Drawing
See page 25
Pressure and Capacity data
Pressure
Flow
Bar kPa Psi L/min USGPM
0
0
0
16.2
0.1
10
1.5 15.1
0.2
20
2.9 13.7
0.3
30
4.4 12.5
0.4
40
5.8 11.3
Fuse required
Amp. draw
12V 24V
4.2
2.0
1.0
4.0
2.3
1.2
3.6
2.8
1.4
3.3
3.4
1.7
3.0
4.0
1.9
8 A
4 A
Original instructions