Kohler K-1695 Manual Del Propieratio página 6

Ocultar thumbs Ver también para K-1695:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Troubleshooting (cont.)
Symptoms
11. Water from steam head.
12. No steam after 5 minutes
of pressing power.
13. Steam stopped.
1069332-5-C
Probable Causes
B. The adaptor is damaged (green
status light on generator is on).
A. Normal operation.
B. Water supply lines are
connected incorrectly.
C. Internal generator components
are not functioning properly.
A. An error has occurred.
B. The temperature setpoint has
already been reached.
C. Inadequate power is supplied to
the generator (green status light
on generator is off).
D. Cables between the generator(s)
and adapter are installed
incorrectly.
E. Steam line or steam head is
blocked.
F.
Generator is damaged.
A. An error has occurred.
B. The session time limit was met
or the temperature setpoint was
met.
Recommended Action
B1. Use the provided test kit and
instructions to identify the source
of the problem.
B2. Call the Customer Care Center
using the information provided on
the back page of this manual.
A1. A small amount of water
discharged from the steamhead just
before, during, and just after steam
use is normal.
A2. Water discharge from the steam
head during the Power Clean cycle
is normal.
B. Review the generator installation
guide and reinstall the lines at the
proper locations.
C. Turn off water supply to the
generator. If possible, drain the
tank. Slowly open the water supply
valve to refill the generator.
C2. Call the Customer Care Center
using the information provided on
the back page of this manual.
A. Check the User Interface for error
messages. If an error message
appears, see the appropriate error
message troubleshooting.
B. Confirm the temperature setpoint is
greater than the current steam
room temperature. Increase the
temperature setpoint if desired.
C1. Provide proper power to the
generator. If necessary use the
provided test kit to ensure the
generator is working properly.
C2. Call the Customer Care Center
using the information provided on
the back page of this manual.
D. Reinstall the black and/or silver
cable(s) between the steam
generator(s) and adapter per the
instructions in the installation
guide.
E. Check the steam head and steam
line for blockages. Repair as
necessary.
F1. Use the provided test kit to check
generator function.
F2. Call the Customer Care Center
using the information provided on
the back page of this manual.
A. Check the User Interface for error
messages. If an error message
appears, see the appropriate error
message troubleshooting.
B. Restart the session timer or increase
the temperature setpoint to restart
steam.
6
Kohler Co.

Publicidad

Tabla de contenido
loading

Tabla de contenido