13. CONNECT WIRING (INTERIOR & EXTERIOR BLOWER)
Risk of electrical shock. Electrical wiring must be done by qualified personnel in accordance with
all applicable codes and standards. Before connecting wires, switch power off at service panel
and lock service disconnecting means to prevent power from being switched on accidentally.
Position insert below the installed custom hood. Pull cable through hole in top of insert.
INTERIOR BLOWER: Remove the cable knock-out on the top of the rough-in plate. Remove rough-in plate
wiring cover. Place the wire clamp in the knock-out hole, insert the cable through the wire clamp in the
rough-in plate wiring box. Tighten the wire clamp to secure the cable.
Connect cable into wiring box using provided wire connectors.
Connect wires as follow: BLACK to BLACK, WHITE to WHITE
and GREEN or BARE wire under ground screw. DO NOT FORGET
TO CONNECT THE GROUND. Reinstall wiring cover.
EXTERIOR BLOWER: Remove rough-in plate wiring cover and connect wiring (see instructions included
with exterior blower).
14. INSTALL THE ROUGH-IN PLATE (INTERIOR & EXTERIOR BLOWER)
INTERIOR BLOWER: Carefully install the rough-in
plate inside the top of the
insert with four (4) lock nuts.
See picture beside.
EXTERIOR BLOWER: Refer to instructions included with 332 KR rough-in plate (sold separately). Secure
the rough-in plate inside the top of the insert with (4) lock nuts.
15. INSTALL THE TRANSITION (INTERIOR BLOWER)
Slide the transition over the adapter/damper. Seal the transition to the
adapter/damper by using duct tape.
WARNING
!
HD0007
1) Ground screw
HD0042
- 8 -
1
HD0091