released (Fig.2).
- Push the blade to the left and upwards at the same time to
remove it from its housing. Then extract downwards.
- Fit the new saw blade, making sure that the teeth are
directed towards the part indicated by the arrow on the blade
cover; fit well to the shaft and lower the moving protection.
Note: if the version of the machine does not have the shaft locking
system as described (the case of the first series manufactured),
the saw blade must be blocked using a bar or a screwdriver in
the hole of the saw blade, leaning against the firm structure of
the machine.
2. REPLACING THE BRUSHES
The brushes must be replaced after every 150 - 200 hours of
use or when they have reached a length of 5-6 mm. Go to an
authorised service centre for this change.
3. REPLACING THE SUPPLY CORD Z2 (Fig.1)
Make sure that the supply cable is in a good state and if not, go to
an authorised service centre for it to be changed.
GUARANTEE
See general Guarantee conditions printed on an adjoining sheet.
DECLARATION OF CONFORMITY
We hereby declare, under our own responsibility, that the
FELISATTI products described in this manual MTF216/1100T
and MTF250/1500T comply with the following standards or
standard documents: EN 61029-1, EN 55014 and EN 61300-3 in
accordance with EU Directives 73/23/EEC, 89/336/EEC, 98/37/
EEC and 2002/95/EEC.
Jordi Carbonell
We reserve the right to make technical changes.
Santiago Lόpez