Troubleshooting - Astralpool VICTORIA PLUS SILENT Manual

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

7. TROUBLESHOOTING

The pump is not primed
1.
The pump only releases a small ow of water
2.
The pump makes a noise
3.
1 2 3 4 5 6
Air entering the suction pipe
Filter cap badly sealed
Motor turning in wrong direction
Wrong voltage
Pre- lter blocked
Load loss in the installation
Pump incorrectly secured
Motor blocked
Increased temperature in the terminal
box due to electric arc
The thermal protection trips
Incorrect junction box connections
10
The pump will not start
4.
The motor is making a noise but will not start
5.
The motor has stopped
6.
CAUSES
Installation and general maintenance manual
SOLUTIONS
Check the condition of connections
and seals on the suction pipe
Clean the lter cap and check the
condition of the rubber seal
Invert 2 power phases
Check the voltage on the rating plate
and that of the mains
Clean the lter
Prevent parts from causing load loss
wherever possible
Secure the pump correctly
Remove the motor and contact the
technical service
Check the junction box connections
Connect the cables correctly to the
junction boxes
Tighten the cable correctly to the
junction box / Adapt the size of the
cable connection to the junction box
- POOL PUMPS

Publicidad

Tabla de contenido
loading

Tabla de contenido